RX62T YROTATE-IT-RX62T Motor Control Kit
UM-YROTATE-IT-RX62T Rev.1.00
Page 48 of 51
Jan 15, 2014
Label(s)
Type
Description
Unit
omegae_s
float
Electrical speed during startup (instant value)
rad/s
delta_om
float
Speed quantity added at every step during startup ramp.
rad/s
om_chg
float
Speed to reach during the startup; when this speed is reached,
the startup ramp ends.
rad/s
startup_phase
float
Electrical phase during startup.
rad
delta_ph
float
Phase variation at every step during startup.
rad
vdx, vqx, vdxf, vqxf
float
D and q axis voltages (instant and filtered) during startup.
volt
idx, iqx, idxf, iqxf
float
D and q axis currents (instant and filtered) during startup.
ampere
SystemPhase
float
Imposed electrical phase.
rad
Phase_est
float
Estimated electrical phase.
rad
vbus, vbusf
float
DC link voltage, instant value and filtered one.
volt
xvbf
float
DC link voltage, min. ripple value, used for voltage clamping.
volt
vfmax
float
Maximum allowed phase voltage (star).
volt
vdmax, vdmax
float
Maximum d and q axis allowed voltages.
i_max, iq_max
float
Max. allowed total current, maximum allowed q axis current.
ampere
vdc, vqc, vdcf, vqcf
float
D and q axis imposed voltages, instant and filtered values.
volt
vac, vbc
float
Alpha and beta axis voltages.
volt
vuc, vvc, vwc
float
Phase voltages (star).
volt
old_va, old_vb
float
Previous step alpha and beta axis voltages.
volt
ium, ivm, iwm
float
Measured phase currents.
ampere
iam, ibm
float
Measured alpha and beta axis currents.
ampere
idm, iqm, idmf,
iqmf
float
Measured d and q axis currents (instant and filtered values).
ampere
idr, iqr
float
D and q axis reference currents.
ampere
id_dec
float
After the startup, the d axis current residual is decreased till
zero; id_dec is the variation at every step.
ampere
idint, iqint
float
Current PI integral memories.
volt
idimem, iqimem
float
Current PI integral memories; this values are used in single
shunt operation to stop the integral action when the current
reading is not possible.
volt