Rev.
Date
Description
Page
Summary
2.20
Dec.01.2016
Program
Fixed the following issue:
Target Device:
RX130/RX230/RX231
Description:
An unnecessary error determination is performed. Because of
this, when setting the disconnection detection assist function
after self-diagnosis is enabled, the R_ADC_Control function
returns an error.
Condition:
Discharge or precharge is selected for the disconnection
detection assist function after self-diagnosis is enabled.
Measure:
Deleted unnecessary determination processing described in the
Description above.
Use Rev. 2.20 or later version of the S12AD FIT module.
Fixed the following issue:
Target Device:
RX63x
Description:
The definition to determine a valid channel is incorrect and
channel 20 cannot be selected.
Condition:
A chip with 177, 176, 145, or 144 pins is selected.
Measure:
Modified the definition to determine a valid channel.
Use Rev. 2.20 or later version of the S12AD FIT module.
Fixed the following issue:
Target Device:
RX631
Description:
There is no definition to determine a valid channel and this
causes a compiling error.
Condition:
A chip with 64 pins or 48 pins is selected.
Measure:
Added the definition to determine a valid channel.
Use Rev. 2.20 or later version of the S12AD FIT module.
Fixed the following issue:
Target Device:
RX64M/RX71M/RX65x
Description:
When obtaining the compare match result, the compare
channel is cleared. Then, the subsequent compare match is not
performed.
Condition:
When any of the unit 1 channel from channel 16 to channel 20
is specified as the compare channel, the condition is met and
the compare match interrupt occurs, or the R_ADC_Control
function is executed by setting
ADC_CMD_CHECK_CONDITION_MET.
Measure:
Modified the register that was initialized when obtaining the
compare match result.
Use Rev. 2.20 or later version of the S12AD FIT module.