RX Family
ADC Module Using Firmware Integration Technology
R01AN1666EJ0220 Rev. 2.20
Page 66 of 74
Dec 01, 2016
Some features may not be used with others. The following table illustrates this.
Dbl
Trig
Group
Scan
Self-
Diag
Add/
Avg
ANEX Sample
&Hold
Priority
GroupA
Sensors Comparator DDA
Double
Trigger
X
*B
X
X
Group Scan
X
*S
Self-
Diagnosis
X
X
X
X
X
Add/Avg
X
ANEX
X
X
X
X
Sample
&Hold
*B
*S
*A
Priority
GroupA
*A
Sensors
X
X
X
Comparator X
X
Disconnect
Detection
Assist
X
X
X
X - Combination may not be used. For example, ANEX may not be used with group scan modes, Self-Diagnosis,
sensors or Disconnect Detection Assist.
*A - Sample and Hold channels must be in Group A.
*B - Sample and Hold channels must be in Group B or Group C.
*S - Sample and Hold channels cannot be split across groups.
Special Notes (RX130/RX230/RX231):
This function does not support following features.
•
Compare function window B
•
Compare function window A/B composite condition setting
Special Notes (RX130/RX230/RX231/RX64M/RX71M/RX65x):
When using the comparison, configure the comparison after the channel configuration.
This function does not support following feature.
•
Group A priority control setting
Special Notes (RX63x):
Only AN008 to AN020 can be used for setting the number of sampling states. AN000 to AN007 are fixed to 20 states
regardless of the setting.
Special Notes (RX110/RX111/RX113):
For temperature sensor and internal reference voltage, the number of sampling states must be set to 5
µ
s or greater.