![Renesas mPD98431 User Manual Download Page 103](http://html.mh-extra.com/html/renesas/mpd98431/mpd98431_user-manual_1440626103.webp)
CHAPTER 5 STATISTICS COUNTERS
User’s Manual S14054EJ4V0UM
101
RBYT - Byte reception counter (register address A[7:0] = 50H) R/W
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
RBYT[31:16]
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
RBYT[15:0]
This counter indicates the byte count of a receive packet. It counts the number of bytes from the destination
address to the FCS byte of the packet. It also counts even if an error occurs.
If a packet exceeding the length set by the LMAX register is received when the HUGEN bit of the MACC1 register
is 0, the value of the LMAX register is counted as the packet length.
RPKT - Packet reception counter (register address A[7:0] = 51H) R/W
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
PRKT[31:16]
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
PRKT[15:0]
This counter counts all the receive packets, including packets in which an error has occurred, all the unicast
packets, all the multicast packets, and all the broadcast packets.
RFCS - CRC error reception counter (register address A[7:0] = 52H) R/W
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
RFCS[31:16]
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
RFCS[15:0]
This counter is incremented when a CRC error occurs in a receive packet.
If a packet exceeding the length set by the LMAX register is received when the HUGEN bit of the MACC1 register
is 0, a CRC check is performed as soon as the set value of the LMAX register is reached, so this may be counted as
the reception of a CRC error.