eng
Explanation of symbols
WARNING
Danger with a medium degree of risk which could result in death or severe injury (irreversible)
if not heeded.
CAUTION
Danger with a low degree of risk which can result in minor injury (reversible) if not heeded.
NOTICE
Material damage, no safety note! No danger of injury.
Read the operating instructions
before
use
Power tool complies with protection class II
Power tool is not suitable for using outdoors
Environmentally friendly disposal
CE conformity mark
1. Technical Data
Use for the intended purpose
WARNING
The power tool is intended for drilling in steel and other metals, stone, wood and plastic, for drilling with REMS tile
drills in ceramics, fine clay, granite and marble, for turning in/loosening screws and for removing burr from pipes
with REMS REG 10 – 42, REMS REG 10 – 54 E. All other uses are not for the intended purpose and are prohibited.
1.1. Scope of delivery
Cordless power drill/ screw driver, Li-Ion rapid charger, battery, 1 bit with double blade slot/cross head, belt
clip (9), operating instructions, carrying bag.
1.2. Article numbers
REMS Helix VE drive unit
190000
Li-Ion 14.4 V, 1.5 Ah battery
571545
Li-Ion 14.4 V, 3.0 Ah battery
571555
Li-Ion/Ni-Cd rapid charger
571560
Li-Ion power supply
571565
Carrying bag
190053
REMS REG 10 – 42, outside/inside pipe deburrer
113810
Driver for REMS REG 10 – 42
113815
REMS REG 10 – 54 E, outside/inside pipe deburrer
113835
REMS tile drill Ø 5 mm
181710
REMS tile drill Ø 6 mm
181711
REMS tile drill Ø 8 mm
181712
REMS tile drill Ø 10 mm
181713
REMS tile drill Ø 12 mm
181714
REMS tile drill Ø 14 mm
181715
REMS CleanM
140119
1.3. Applications
Clamping range quick-clamping chuck
0.8 – 10 mm
Drilling in steel, stone
Ø ≤ 10 mm
Drilling in wood
Ø ≤ 28 mm
Drilling with tile drills
Ø ≤ 14 mm
Turning in/loosening screws
Ø ≤ 7 mm
Operating temperature range
REMS Helix VE
0 °C – +60 °C (32 °F – +140 °F)
Li-Ion Plus battery
–10 °C – +60 °C (14 °F – +140 °F)
Li-Ion/Ni-Cd rapid charger
0 °C – +40 °C (32 °F – +104 °F)
15
Summary of Contents for Helix VE
Page 2: ...Fig 1 6 5 8 4 1 2 3 7 9 2...
Page 165: ...1 1 2 3 Hi Lo 4 5 6 7 8 9 1 a b c 2 a b c d e f 3 a b rus 165...
Page 166: ...rus c d e f g 4 a b c d e f g 5 a b c d 6 a 166...
Page 167: ...rus 7 Hi Lo 4 5 6 FFP2 16 REMS 10 1 5 10 30 2 5 167...
Page 168: ...rus REMS REMS REMS REMS REMS REMS 6 A 168...
Page 174: ...rus 6 REMS Helix VE 7 12 REMS REMS REMS REMS CISG 8 www rems de 5 5 2 2 2 4 174...
Page 175: ...1 1 2 3 Hi Lo 4 5 6 LED 7 8 9 1 a 2 3 ell 175...
Page 176: ...4 5 6 ell 176...
Page 177: ...7 Hi Lo 4 5 LED 6 FFP2 16 REMS 10 m 1 5 mm 10 30 m 2 5 mm LED REMS REMS LED ell 177...
Page 178: ...ell REMS REMS REMS LED REMS 6 II CE 178...
Page 193: ...1 1 2 3 Hi Lo 4 5 6 7 8 9 1 a 2 a 3 a bul 193...
Page 194: ...bul 4 a 5 a 6 a 194...
Page 195: ...bul 7 Hi Lo 4 5 6 FFP2 16 REMS 10 m 1 5 mm 10 30 m 2 5 mm REMS 195...
Page 196: ...bul REMS REMS REMS REMS REMS 6 A 196...
Page 202: ...bul 6 REMS Helix VE 7 12 REMS REMS REMS REMS CISG 8 www rems de Downloads Parts lists 202...
Page 230: ...230...