background image

NEVER LEAVE HEATER UNATTENDED WHILE BURNING, 

CONNECTED TO A POWER SOURCE, OR WHILE CONNECTED TO A 

FUEL SOURCE.

© 2018 Pinnacle Climate Technologies, Inc. 

Cabinet Heater User's Manual

3

SAFETY INFORMATION (CONT.)

The products described in this manual are pro-

pane direct-fired, forced air heaters. Propane 

forced air heaters are primarily intended for use 

for temporary heating of buildings under con-

struction, alteration or repair. Direct-fired means 

that all of the combustion products of the 

heater enter the heated space. This appliance 

is rated at 98% combustion efficiency, but does 

produce small amounts of carbon monoxide.

Carbon monoxide is toxic. Humans can tolerate 

only small amounts of carbon monoxide and so 

precautions should be taken to provide proper 

ventilation. Failure to provide proper ventilation 

in accordance with the instructions in this manu-

al can result in death.

People with breathing problems should consult 

a physician before using this heater. 

Early signs of carbon monoxide poisoning re-

semble the flu. Symptoms of improper ventila-

tion / carbon monoxide poisoning are:

Headache • Dizziness • Nausea • Dry Mouth 

Sore Throat • Burning of Nose and Eyes

If you experience any of these symptoms: 

GET FRESH AIR AT ONCE! 

Have your heater 

serviced and check for proper ventilation. Some 

people are more affected by carbon monoxide 

than others. These include: pregnant women, 

those with heart or lung problems, anemia or 

those under the influence of alcohol or at high 

altitudes. 
FOR OUTDOOR USE. INDOOR USE 

PERMITTED ONLY FOR: The temporary heating 

of adequately ventilated buildings or structures 

under construction, alteration or repair! Provide 

at least a three square foot (2,800 sq cm) 

opening of outside air for every 100,000 Btu / Hr 

heater rating. Refer to “Ventilation” on page 9 

for further instructions.

WHAT TO DO IF THE SMELL OF GAS IS PRESENT:

 

DO NOT attempt to light the heater.

 

Extinguish any open flame.

 

Shut off gas to heater.

 

If odor continues, contact your local gas 

supplier or fire department.

 

DO NOT touch or use any electric switch or 

any electric device that can cause a spark.

 

Immediately call your gas supplier from a 

neighbors phone. Follow the gas suppliers 

instructions.

 

If you can not reach your gas supplier, call 

the fire department. 

 

Service must be done by a qualified service 

agency.

NEVER store or use gasoline or other flammable 

vapors and liquids in the vicinity of this heater.

NEVER store a propane (LP) cylinder not connected 

to this heater in the vicinity of this heater.

NEVER connect heater to an unregulated gas 

supply.

NEVER obstruct the flow of combustion and 

ventilation air. 

NEVER use duct work in front or rear of heater.

NEVER modify this heater or operate a heater that 

has been modified.

NEVER service, move or handle heater while still 

hot or operating

Keep all combustible materials away from this 

heater.

Minimum Clearance From Combustibles

Front

Sides

Top

72 in.

12 in.

24 in.

RISK OF BURNS, 

FIRE AND EXPLO-

SION!

PROPANE IS AN  

EXPLOSIVE GAS.

DANGER

WARNING

CAUTION! 

HOT WHILE IN 

OPERATION. DO 

NOT TOUCH. KEEP CHILDREN, ANIMALS, 

CLOTHING AND COMBUSTIBLES AWAY 

FROM HEATER. 

WARNING

RISK OF INDOOR 

AIR POLLUTION!

WARNING

CARBON 

MONOXIDE 

POISONING MAY 

LEAD TO DEATH!

DANGER

Summary of Contents for REM-18-PCH-B

Page 1: ...R OR CARDBOARD A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THESE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES OR PRODUCTS SUCH AS GA...

Page 2: ...s product can expose you to chemicals including lead which are known to the State of California to cause cancer and birth defects or other reproductive harm For more information go to www P65Warnings...

Page 3: ...DOOR USE PERMITTED ONLY FOR The temporary heating of adequately ventilated buildings or structures under construction alteration or repair Provide at least a three square foot 2 800 sq cm opening of o...

Page 4: ...y Do not convert to any other gas Installation must conform to local codes or in their absence with the standard for the Storage and Handling of Liquefied Petroleum Gases ANSI NFPA 58 and the Natural...

Page 5: ...ment Keep plastic cover caps attached to inlet connector and hose regulator assembly for storage 2 Remove all items from carton 3 Check all items for shipping damage If the heater is damaged promptly...

Page 6: ...hose and regulator assembly sup plied 1 Remove the back cover by sliding the cover straight up and away from the heater body Place the LP cylinder on the bottom plate and replace the back cover 2 To c...

Page 7: ...ipping the LP cylinder on its side when connected to a regulator since this may cause damage to diaphragm in the regulator Handle valves with care Never connect an unregulated LP cylinder to a constru...

Page 8: ...on Keep gasoline and any other flammable liquids away from the heater WARNING Lighting Instructions 1 STOP Read all of the safety information provided with this heater 2 Turn valve on propane cylinder...

Page 9: ...rakes push the lever down on each wheel To move the heater release the brakes simply by flipping the levers on both brakes up OPERATION CONT Risk of indoor air pollution and Carbon Monoxide Poisoning...

Page 10: ...th your heater and re package the heater using these materials for safe storage Debris dust and dirt inside of the heater body can affect the performance of your heater This debris can impair the heat...

Page 11: ...der valve Wait 1 min for switch to click off Reopen LP cylinder valve slowly 7 Move heater to a level surface No spark created when ignited 1 Incorrect igniter electrode position 2 Electrode damaged o...

Page 12: ...OWER SOURCE OR WHILE CONNECTED TO A FUEL SOURCE 2018 Pinnacle Climate Technologies Inc Cabinet Heater User s Manual 12 1 2 3 EXPLODED VIEW PARTS LIST Item Description REM 18 PCH B 1 Front Castor 50 01...

Page 13: ...the item freight pre paid If Pinnacle Climate Technologies Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in...

Page 14: ...1 Industrial Blvd 101 Sauk Rapids MN 56379 USA Toll Free 800 641 6996 Fax 320 251 2922 Web www remingtonheater com Email info pinnacleclimate com 2018 Pinnacle Climate Technologies Inc...

Page 15: ...UX DE CONSTRUCTION LE PAPIER OU LE CARTON UNE DISTANCE S CURITAIRE DE LA CHAUFFERETTE COMME RECOMMAND DANS LES PR SENTES INSTRUCTIONS NE JAMAIS UTILISER LA CHAUFFERETTE DANS DES ENDROITS QUI CONTIENNE...

Page 16: ...en de cette chaufferette AVERTISSEMENT Ce produit peut vous exposer des produits chimiques notamment du plomb reconnus dans l tat de Californie comme cause de cancer de malformations cong nitales ou d...

Page 17: ...raire des structures ou des b timents bien ventil s en cours de construction de modification ou de r paration Une ouverture d un minimum de 2 800 cm sur l air ext rieur doit exister pour chaque 29 kWh...

Page 18: ...e GPL exclusivement Ne pas la convertir pour un autre gaz L installation doit tre conforme aux codes locaux ou en leur absence avec la norme du Storage and Handling of Liquefied Petroleum Gases ANSI N...

Page 19: ...plastique attach s l ensemble connecteur d entr e et tuyau r gulateur pour l entreposage 2 Enlever tous les articles du carton 3 V rifier qu aucun article n a t endommag pendant le transport Si la ch...

Page 20: ...ulateur fourni 1 Ouvrir le capot arri re en le glissant vers le haut hors du bo tier de la chaufferette Placer la bouteille de propane sur la plaque inf rieure et replacer le capot arri re 2 Raccorder...

Page 21: ...mmager le diaphragme l int rieur du r gulateur Manipuler les robinets avec pr caution Ne jamais raccorder une bouteille de propane sans r gulateur une chaufferette de construction NE PAS soumettre la...

Page 22: ...iquide inflammable loin de la chaufferette Instructions d allumage 1 ARR TER Lire toutes les consignes de s curit fournies avec cette chaufferette 2 Tourner le robinet de la bouteille de propane dans...

Page 23: ...sur le levier de chaque roulette Pour d placer la chaufferette rel cher les freins en relevant simplement le levier des deux roulettes MODE D EMPLOI SUITE Risque de pollution de l air int rieur et d...

Page 24: ...Les d bris la poussi re et les salet s l int rieur du bo tier de la chaufferette peuvent nuire son rendement De tels d bris peuvent r duire la capacit de l appareil aspirer de l air pour la ventilati...

Page 25: ...uteille de GPL Attendre une minute que l interrupteur s ouvre Rouvrir le robinet de la bouteille 7 Replacer l appareil sur une surface plane Aucune tincelle produite lors de l allumage 1 Position inco...

Page 26: ...UNE SOURCE D ALIMENTATION OU DE COMBUSTIBLE 2018 Pinnacle Climate Technologies Inc Manuel de la chaufferette cabinet 12 1 2 3 VUE CLAT E LISTE DES PI CES No de r f Description REM 18 PCH B 1 Roulette...

Page 27: ...il est d fectueux Pinnacle Climate Technologies Inc r parera ou remplacera et retournera l article en port pay Si Pinnacle Climate Technologies Inc d termine que l article est dans un tat d utilisatio...

Page 28: ...Industrial Blvd 101 Sauk Rapids MN 56379 USA Num ro sans frais 800 641 6996 T l copieur 320 251 2922 Web www remingtonheater com Courriel info pinnacleclimate com 2018 Pinnacle Climate Technologies In...