background image

NEVER LEAVE HEATER UNATTENDED WHILE BURNING, 

CONNECTED TO A POWER SOURCE, OR WHILE CONNECTED TO A 

FUEL SOURCE.

© 2018 Pinnacle Climate Technologies, Inc. 

Cabinet Heater User's Manual

13

LIMITED WARRANTY

Pinnacle Climate Technologies, Inc.

 warrants this heater 

to the original retail purchaser only, to be free from 

defects in material and workmanship for a period of one 

(1) year from the date of initial purchase. This product 

must be properly installed, maintained and operated in 

accordance with the instructions provided.

Pinnacle Climate Technologies, Inc. 

requires reasonable 

proof of your date of purchase from an authorized retailer 

or distributor. Therefore, you should keep your sales slip, 

invoice or cancelled check from the original purchase.  

This Limited Warranty shall be limited to the repair or 

replacement of parts, which prove defective under normal 

use and service within the warranty period, and which 

Pinnacle Climate Technologies , Inc.

 shall determine at its 

reasonable discretion. 

This warranty does not apply to products purchased for 

rental use. 

This Limited Warranty does not cover any failures or 

operating difficulties due to normal wear and tear, 

accident, abuse, misuse, alteration, misapplication, 

improper installation or improper maintenance and 

service by you or any third party.  Failure to perform 

normal and routine maintenance on the heater, shipping 

damage, damage related to insects, birds or animals of 

any kind, and damage due to weather conditions are also 

not covered.  

In addition, the Limited Warranty does not cover damage 

to the finish, such as scratches, dents, discoloration, rust 

or other weather damage, after purchase. 

All transportation costs for the return of damaged 

product or parts will be the responsibility of the 

purchaser. Upon receipt of damaged item, 

Pinnacle 

Climate Technologies, Inc. 

will examine the item and 

determine if defective. 

Pinnacle Climate Technologies, 

Inc. 

will repair or replace and return the item, freight pre-

paid.

 

If 

Pinnacle Climate Technologies, Inc. 

finds the item 

to be in normal operating condition, or not defective 

the item will be returned freight collect. This Limited 

Warranty is in lieu of all other express warranties. 

Pinnacle Climate Technologies, Inc.

 disclaims all 

warranties for products that are purchased from sellers 

other than authorized dealers or distributors. 

AFTER THE PERIOD OF THE ONE (1) YEAR EXPRESS 

WARRANTY EXPIRES, 

Pinnacle Climate Technologies, 

Inc. 

DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, 

INCLUDING WITHOUT LIMITATION THE IMPLIED 

WARRANTIES OF MERCHANTABILITY AND FITNESS 

FOR A PARTICULAR APPLICATION. FURTHER, 

Pinnacle 

Climate Technologies, Inc. 

SHALL HAVE NO LIABILITY 

WHATSOEVER TO PURCHASER OR ANY THIRD PARTY 

FOR ANY SPECIAL, INDIRECT, PUNITIVE INCIDENTAL, 

OR CONSEQUENTIAL DAMAGES. 

Pinnacle Climate 

Technologies, Inc. 

assumes no responsibility for any 

defects caused by third parties. This Limited Warranty 

gives the purchaser specific legal rights; a purchaser 

may have other rights depending upon where he or she 

lives. Some states do not allow the exclusion or limitation 

of special, incidental or consequential damages, or 

limitations on how long a warranty lasts, so the above 

exclusion and limitations may not apply to you.  

Pinnacle Climate Technologies, Inc. 

does not authorize 

any person or company to assume for it any other 

obligation or liability in connection with the sale, 

installation, use, removal, return or replacement of its 

equipment, and no such representations are binding on 

Pinnacle Climate Technologies, Inc.

Always be sure to specify the model number and serial 

number when making any claim with 

Pinnacle Climate 

Technologies, Inc. 

For your convenience, use the space 

provided below to list this information.

Model #:________________________________

Serial #:________________________________

Date of Purchase: ________________________

Locating Your Serial Number:

Your serial number can be found on the heater’s rating label. It will begin with the letters PGCV 

followed by 8 digits. For Example: PGCV12345678. Have your Serial Number ready before calling 

customer service at 1-800-641-6996.

Summary of Contents for REM-18-PCH-B

Page 1: ...R OR CARDBOARD A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THESE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES OR PRODUCTS SUCH AS GA...

Page 2: ...s product can expose you to chemicals including lead which are known to the State of California to cause cancer and birth defects or other reproductive harm For more information go to www P65Warnings...

Page 3: ...DOOR USE PERMITTED ONLY FOR The temporary heating of adequately ventilated buildings or structures under construction alteration or repair Provide at least a three square foot 2 800 sq cm opening of o...

Page 4: ...y Do not convert to any other gas Installation must conform to local codes or in their absence with the standard for the Storage and Handling of Liquefied Petroleum Gases ANSI NFPA 58 and the Natural...

Page 5: ...ment Keep plastic cover caps attached to inlet connector and hose regulator assembly for storage 2 Remove all items from carton 3 Check all items for shipping damage If the heater is damaged promptly...

Page 6: ...hose and regulator assembly sup plied 1 Remove the back cover by sliding the cover straight up and away from the heater body Place the LP cylinder on the bottom plate and replace the back cover 2 To c...

Page 7: ...ipping the LP cylinder on its side when connected to a regulator since this may cause damage to diaphragm in the regulator Handle valves with care Never connect an unregulated LP cylinder to a constru...

Page 8: ...on Keep gasoline and any other flammable liquids away from the heater WARNING Lighting Instructions 1 STOP Read all of the safety information provided with this heater 2 Turn valve on propane cylinder...

Page 9: ...rakes push the lever down on each wheel To move the heater release the brakes simply by flipping the levers on both brakes up OPERATION CONT Risk of indoor air pollution and Carbon Monoxide Poisoning...

Page 10: ...th your heater and re package the heater using these materials for safe storage Debris dust and dirt inside of the heater body can affect the performance of your heater This debris can impair the heat...

Page 11: ...der valve Wait 1 min for switch to click off Reopen LP cylinder valve slowly 7 Move heater to a level surface No spark created when ignited 1 Incorrect igniter electrode position 2 Electrode damaged o...

Page 12: ...OWER SOURCE OR WHILE CONNECTED TO A FUEL SOURCE 2018 Pinnacle Climate Technologies Inc Cabinet Heater User s Manual 12 1 2 3 EXPLODED VIEW PARTS LIST Item Description REM 18 PCH B 1 Front Castor 50 01...

Page 13: ...the item freight pre paid If Pinnacle Climate Technologies Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in...

Page 14: ...1 Industrial Blvd 101 Sauk Rapids MN 56379 USA Toll Free 800 641 6996 Fax 320 251 2922 Web www remingtonheater com Email info pinnacleclimate com 2018 Pinnacle Climate Technologies Inc...

Page 15: ...UX DE CONSTRUCTION LE PAPIER OU LE CARTON UNE DISTANCE S CURITAIRE DE LA CHAUFFERETTE COMME RECOMMAND DANS LES PR SENTES INSTRUCTIONS NE JAMAIS UTILISER LA CHAUFFERETTE DANS DES ENDROITS QUI CONTIENNE...

Page 16: ...en de cette chaufferette AVERTISSEMENT Ce produit peut vous exposer des produits chimiques notamment du plomb reconnus dans l tat de Californie comme cause de cancer de malformations cong nitales ou d...

Page 17: ...raire des structures ou des b timents bien ventil s en cours de construction de modification ou de r paration Une ouverture d un minimum de 2 800 cm sur l air ext rieur doit exister pour chaque 29 kWh...

Page 18: ...e GPL exclusivement Ne pas la convertir pour un autre gaz L installation doit tre conforme aux codes locaux ou en leur absence avec la norme du Storage and Handling of Liquefied Petroleum Gases ANSI N...

Page 19: ...plastique attach s l ensemble connecteur d entr e et tuyau r gulateur pour l entreposage 2 Enlever tous les articles du carton 3 V rifier qu aucun article n a t endommag pendant le transport Si la ch...

Page 20: ...ulateur fourni 1 Ouvrir le capot arri re en le glissant vers le haut hors du bo tier de la chaufferette Placer la bouteille de propane sur la plaque inf rieure et replacer le capot arri re 2 Raccorder...

Page 21: ...mmager le diaphragme l int rieur du r gulateur Manipuler les robinets avec pr caution Ne jamais raccorder une bouteille de propane sans r gulateur une chaufferette de construction NE PAS soumettre la...

Page 22: ...iquide inflammable loin de la chaufferette Instructions d allumage 1 ARR TER Lire toutes les consignes de s curit fournies avec cette chaufferette 2 Tourner le robinet de la bouteille de propane dans...

Page 23: ...sur le levier de chaque roulette Pour d placer la chaufferette rel cher les freins en relevant simplement le levier des deux roulettes MODE D EMPLOI SUITE Risque de pollution de l air int rieur et d...

Page 24: ...Les d bris la poussi re et les salet s l int rieur du bo tier de la chaufferette peuvent nuire son rendement De tels d bris peuvent r duire la capacit de l appareil aspirer de l air pour la ventilati...

Page 25: ...uteille de GPL Attendre une minute que l interrupteur s ouvre Rouvrir le robinet de la bouteille 7 Replacer l appareil sur une surface plane Aucune tincelle produite lors de l allumage 1 Position inco...

Page 26: ...UNE SOURCE D ALIMENTATION OU DE COMBUSTIBLE 2018 Pinnacle Climate Technologies Inc Manuel de la chaufferette cabinet 12 1 2 3 VUE CLAT E LISTE DES PI CES No de r f Description REM 18 PCH B 1 Roulette...

Page 27: ...il est d fectueux Pinnacle Climate Technologies Inc r parera ou remplacera et retournera l article en port pay Si Pinnacle Climate Technologies Inc d termine que l article est dans un tat d utilisatio...

Page 28: ...Industrial Blvd 101 Sauk Rapids MN 56379 USA Num ro sans frais 800 641 6996 T l copieur 320 251 2922 Web www remingtonheater com Courriel info pinnacleclimate com 2018 Pinnacle Climate Technologies In...