background image

NEVER LEAVE HEATER UNATTENDED WHILE BURNING, 

CONNECTED TO A POWER SOURCE, OR WHILE CONNECTED TO A 

FUEL SOURCE.

© 2018 Pinnacle Climate Technologies, Inc. 

Cabinet Heater User's Manual

7

OPERATION

Propane Supply / Information:

Propane (LP)

This heater is not supplied with a propane cylinder. 

Use only an approved propane cylinder.

LP Characteristics

 

– Flammable, explosive under pressure, heavier than 

air and pools in low areas.

 

– In its natural state, propane has no odor, but for 

your safety an odor that smells like rotten cabbage 

has been added.

 

– Contact of propane (LP) gas with the skin can 

cause freeze burns.

 

– Heater is manufactured for use with propane gas 

only. DO NOT attempt to convert to any other 

gas. Such modifications are dangerous and will 

void the warranty.

 

– When heater is not in use, LP Cylinder must be 

turned OFF.

 

– Be sure that the LP Cylinder is located on a level 

and stable surface.

 

– DO NOT use this heater in a basement or below 

ground level. Propane is heavier than air and will 

always seek the lowest level. If you suspect a leak, 

shut off the valve at the LP Cylinder immediately.

The Propane (LP) cylinder must also be equipped 

with the following:

 

– A collar to protect the gas valve.

 

– A shut-off valve terminating a LP cylinder valve 

outlet as specified in the American National 

Standard for Compressed Gas Cylinder Valve 

Outlets and Inlets Connections.

 

– A safety relief valve having direct communications 

with the vapor space of the LP cylinder.

 

– The heater must operate on vapor withdrawal 

from the operating cylinder.

 

– Always keep LP cylinder fastened and upright.

 

– Avoid tipping the LP cylinder on its side when 

connected to a regulator, since this may cause 

damage to diaphragm in the regulator.

 

– Handle valves with care.

 

– Never connect an unregulated LP cylinder to a 

construction heater.

 

– DO NOT subject LP cylinder to excessive heat.

 

– Tightly close the gas shutoff valve on the LP 

cylinder after each use. 

 

– All fittings must be protected when disconnected 

from the LP cylinder.

 

– Never store an LP cylinder inside a building or in 

the vicinity of an gas burning appliances.

Pre-Lighting Instructions:

Connecting the LP Cylinder

ALL NEW LP CYLINDERS MUST BE PURGED 

BEFORE THE FIRST FILLING.

 

– Turn heater gas valve knob and LP cylinder valve 

to OFF position.

 

– LP cylinder valve equipped with old style fitting 

has LEFT HANDED THREADS. Turn fitting 

CLOCKWISE to loosen. Protect this fitting when 

disconnected from LP cylinder.

 

– Have your LP cylinder filled by your local 

propane gas supplier.

 

– Some LP cylinders have a bleed-OFF valve. This 

valve should be inspected for leaks after each 

filling of the LP cylinder. Turn the valve clockwise 

to close.

 

– Fasten full propane tank and connect proper 

fitting to LP cylinder valve by turning COUNTER-

CLOCKWISE.

 

– With heater gas valve knob still in OFF position 

turn ON the LP cylinder valve and check for leaks 

with soap solution.

Propane is 

safe to use 

when properly 

handled. Careless handling of the LP 

cylinder could result in a fire and or an 

explosion.

CAUTION

The disconnected 

tank must never 

be stored in a 

building, garage or any other enclosed 

area.

CAUTION

Purging and 

filling of the LP 

cylinders must be 

performed by personnel who have been 

thoroughly trained in accepted LP gas 

industry procedures. Failure to follow 

these instructions may result in explosion, 

fire, severe personal injury or death. 

WARNING

Summary of Contents for REM-18-PCH-B

Page 1: ...R OR CARDBOARD A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THESE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES OR PRODUCTS SUCH AS GA...

Page 2: ...s product can expose you to chemicals including lead which are known to the State of California to cause cancer and birth defects or other reproductive harm For more information go to www P65Warnings...

Page 3: ...DOOR USE PERMITTED ONLY FOR The temporary heating of adequately ventilated buildings or structures under construction alteration or repair Provide at least a three square foot 2 800 sq cm opening of o...

Page 4: ...y Do not convert to any other gas Installation must conform to local codes or in their absence with the standard for the Storage and Handling of Liquefied Petroleum Gases ANSI NFPA 58 and the Natural...

Page 5: ...ment Keep plastic cover caps attached to inlet connector and hose regulator assembly for storage 2 Remove all items from carton 3 Check all items for shipping damage If the heater is damaged promptly...

Page 6: ...hose and regulator assembly sup plied 1 Remove the back cover by sliding the cover straight up and away from the heater body Place the LP cylinder on the bottom plate and replace the back cover 2 To c...

Page 7: ...ipping the LP cylinder on its side when connected to a regulator since this may cause damage to diaphragm in the regulator Handle valves with care Never connect an unregulated LP cylinder to a constru...

Page 8: ...on Keep gasoline and any other flammable liquids away from the heater WARNING Lighting Instructions 1 STOP Read all of the safety information provided with this heater 2 Turn valve on propane cylinder...

Page 9: ...rakes push the lever down on each wheel To move the heater release the brakes simply by flipping the levers on both brakes up OPERATION CONT Risk of indoor air pollution and Carbon Monoxide Poisoning...

Page 10: ...th your heater and re package the heater using these materials for safe storage Debris dust and dirt inside of the heater body can affect the performance of your heater This debris can impair the heat...

Page 11: ...der valve Wait 1 min for switch to click off Reopen LP cylinder valve slowly 7 Move heater to a level surface No spark created when ignited 1 Incorrect igniter electrode position 2 Electrode damaged o...

Page 12: ...OWER SOURCE OR WHILE CONNECTED TO A FUEL SOURCE 2018 Pinnacle Climate Technologies Inc Cabinet Heater User s Manual 12 1 2 3 EXPLODED VIEW PARTS LIST Item Description REM 18 PCH B 1 Front Castor 50 01...

Page 13: ...the item freight pre paid If Pinnacle Climate Technologies Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in...

Page 14: ...1 Industrial Blvd 101 Sauk Rapids MN 56379 USA Toll Free 800 641 6996 Fax 320 251 2922 Web www remingtonheater com Email info pinnacleclimate com 2018 Pinnacle Climate Technologies Inc...

Page 15: ...UX DE CONSTRUCTION LE PAPIER OU LE CARTON UNE DISTANCE S CURITAIRE DE LA CHAUFFERETTE COMME RECOMMAND DANS LES PR SENTES INSTRUCTIONS NE JAMAIS UTILISER LA CHAUFFERETTE DANS DES ENDROITS QUI CONTIENNE...

Page 16: ...en de cette chaufferette AVERTISSEMENT Ce produit peut vous exposer des produits chimiques notamment du plomb reconnus dans l tat de Californie comme cause de cancer de malformations cong nitales ou d...

Page 17: ...raire des structures ou des b timents bien ventil s en cours de construction de modification ou de r paration Une ouverture d un minimum de 2 800 cm sur l air ext rieur doit exister pour chaque 29 kWh...

Page 18: ...e GPL exclusivement Ne pas la convertir pour un autre gaz L installation doit tre conforme aux codes locaux ou en leur absence avec la norme du Storage and Handling of Liquefied Petroleum Gases ANSI N...

Page 19: ...plastique attach s l ensemble connecteur d entr e et tuyau r gulateur pour l entreposage 2 Enlever tous les articles du carton 3 V rifier qu aucun article n a t endommag pendant le transport Si la ch...

Page 20: ...ulateur fourni 1 Ouvrir le capot arri re en le glissant vers le haut hors du bo tier de la chaufferette Placer la bouteille de propane sur la plaque inf rieure et replacer le capot arri re 2 Raccorder...

Page 21: ...mmager le diaphragme l int rieur du r gulateur Manipuler les robinets avec pr caution Ne jamais raccorder une bouteille de propane sans r gulateur une chaufferette de construction NE PAS soumettre la...

Page 22: ...iquide inflammable loin de la chaufferette Instructions d allumage 1 ARR TER Lire toutes les consignes de s curit fournies avec cette chaufferette 2 Tourner le robinet de la bouteille de propane dans...

Page 23: ...sur le levier de chaque roulette Pour d placer la chaufferette rel cher les freins en relevant simplement le levier des deux roulettes MODE D EMPLOI SUITE Risque de pollution de l air int rieur et d...

Page 24: ...Les d bris la poussi re et les salet s l int rieur du bo tier de la chaufferette peuvent nuire son rendement De tels d bris peuvent r duire la capacit de l appareil aspirer de l air pour la ventilati...

Page 25: ...uteille de GPL Attendre une minute que l interrupteur s ouvre Rouvrir le robinet de la bouteille 7 Replacer l appareil sur une surface plane Aucune tincelle produite lors de l allumage 1 Position inco...

Page 26: ...UNE SOURCE D ALIMENTATION OU DE COMBUSTIBLE 2018 Pinnacle Climate Technologies Inc Manuel de la chaufferette cabinet 12 1 2 3 VUE CLAT E LISTE DES PI CES No de r f Description REM 18 PCH B 1 Roulette...

Page 27: ...il est d fectueux Pinnacle Climate Technologies Inc r parera ou remplacera et retournera l article en port pay Si Pinnacle Climate Technologies Inc d termine que l article est dans un tat d utilisatio...

Page 28: ...Industrial Blvd 101 Sauk Rapids MN 56379 USA Num ro sans frais 800 641 6996 T l copieur 320 251 2922 Web www remingtonheater com Courriel info pinnacleclimate com 2018 Pinnacle Climate Technologies In...

Reviews: