background image

Page 3

Energy Savings Beyond Energy Efficiency Rating (E.E.R.)

The Digital Temperature Set Point allows each occupant
to easily set their precise desired zone comfort tempera-
ture. Eliminating the zone comfort guesswork inherent
with mechanical knob controls decreases unnecessary
running of the unit and helps prevent expensive over-
cooling/overheating.

Standard Flexible Control Module

The Remington unit has a flexible control module. This
allows the digital control pad to be removed and mount-
ed within the room on a wall within the occupied space.
Additionally, the standard features and functionality of
the controls are a superior value versus the mechanical
knobs most other PTAC's use.

Corrosion Resistant Hydrophilic Coils

On Remington units, all evaporator and condenser coils
are protected with a hydrophilic coating. This feature is
standard on all Remington units, making it an ideal
choice for any environment, including highly corrosive
environments such as Florida. This protection can also
extend the life of your coils, offering added cost savings.

Classroom Benefits

Remington units' standard features provide exceptional
benefits for classroom applications. There are no knobs
for students to remove and lose. Remington's two-motor
units are inherently quieter than a single motor design.
The Remington unit is pencil proof. The Fresh Air
Damper also arrives without additional labor required to
enable the damper.

Extra Humidity Control

Remington is the only AC manufacturer to offer the Cool-
Dry Dehumidification Mode standard on all units. The
system is designed to provide high indoor air quality
(IAQ) by reducing humidity which can help to prevent
mold/mildew build-up in conditioned space. As a result,
the conditioned air will feel and smell fresher, removing
up to 70% more humidity in the Cool-Dry mode when
compared to the standard cool mode at 50% load.
Results will vary under different loading conditions.

A Superior Choice

Remington units meet the industry standard (ASHRAE
90.1) for E.E.R.’s and capacities, and they offer much
more than that. Our money-saving operational features,
combined with our superior warranty packages, can pay
dividends both in labor savings and operational costs in
the long run.

Warranty

No other manufacturer stands behind their product like
Remington. Both our Gold Plus and Platinum Plus
Packages offer a limited one-year unit exchange warran-
ty on the entire conditioner and a refrigeration circuit unit
exchange warranty for the 2

nd

through 5

th

year. The Gold

Plus package offers an additional functional parts war-
ranty for the 2

nd

through 5

th

year. Freight costs will be

paid by the manufacturer. Please contact us for more
warranty package details.

The New Remington

®

16 x 42 PTAC/PTHP Series Unit...Our Advantages

Remington's contemporary design is both attractive and thoughtful - with standard 
features like solid-state electronic touch pad controls that are easy to operate and 
provide precise comfort settings.

Summary of Contents for Amana PTC

Page 1: ...Packaged Terminal Air Conditioners and Heat Pumps Architects and Engineers Manual...

Page 2: ...p Front Cleanable Filter Standard Standard Standard Standard Standard Standard Standard Standard Automatic Indoor Frost Control Standard Standard Standard Standard Standard Option Corrosion Treated Ch...

Page 3: ...llation page 14 Drain Kit Installation page 15 Unit Dimensions page 16 Table of Contents Bi Directional Discharge Grille High Efficiency Refrigeration Coils Chassis Fits Any Standard 16 H x 42 W x 133...

Page 4: ...Costs The overall system design is greatly simplified allowing designers to devote more time to other areas and reducing overall costs Architectural Design Freedom Eliminates the need for large mecha...

Page 5: ...ditional labor required to enable the damper Extra Humidity Control Remington is the only AC manufacturer to offer the Cool Dry Dehumidification Mode standard on all units The system is designed to pr...

Page 6: ...H x 42 W x 133 4 D wall opening Remington conditioners are compatible with most existing wall thermostats and remote control interfaces for added savings on installation labor and costs Insulated wall...

Page 7: ...for guest comfort and energy savings Automatically controls unit shut off after a specified time 1 to 15 hours Adjustable minimum and maximum room temperature set points Allows wireless remote contro...

Page 8: ...ectly connected to a two speed motor All fans shall be statically and dynamically bal anced to provide for quiet and smooth operation During the cooling cycle the compressor and both fan motors shall...

Page 9: ...ours This will automatically compensate for the cold or warm radiation effect felt from the mass in the walls floor and furnishings until they normalize The 2 F offset is maintained for the first cycl...

Page 10: ...disconnects are also available To ease field installation subbase must have adjustable side channels with predrilled adjusting holes and score lines Additionally subbase shall have adjustable levelin...

Page 11: ...65V models and is optional for 208V 230V models Figure 1 shows the subbase and dimensions Power Supply Wiring All wiring must be done in accordance with all local and National Electrical Code requirem...

Page 12: ...select the number of hours 1 15 after which the unit will turn off To turn the unit on preset the unit to the desired mode and temperature and turn it off Press the TIMER key repeatedly to select the...

Page 13: ...ll sleeve applications 111 2 D that do not conform to industry standard depth 133 4 D Drain Kits Internal or external mounted drain kits Pre drilled wall sleeve simplifies drain kit installation Subba...

Page 14: ...Amps 18 5 20 7 18 0 18 5 20 7 18 5 Capacity Btuh 7 100 7 400 7 300 8 900 8 900 8 900 11 000 11 400 11 400 14 000 14 500 14 400 Cooling EER 11 6 11 5 10 7 10 6 10 4 10 4 10 0 9 9 10 1 9 3 9 3 9 2 Full...

Page 15: ...Page 13 Wiring Diagrams Model PTAC 07B 09B 12B 15B...

Page 16: ...wall and panel wall applications for positive anchoring to the wall For thicker walls wall sleeve extensions are available from your local Remington representative Air splitters must be included in w...

Page 17: ...wall sleeve has been installed Note When using the ex ternal drain kit the sleeve must be flush or beyond the out side finished wall do not recess Install the external drain kit as follows 1 Assemble...

Page 18: ...available in 3 or 4 height with depth adjustable from 43 8 to 133 4 Unit pictured with subbase installed but can also be floor mounted without subbase for 208V 230V applications Side View Top View Fro...

Page 19: ...m Blue MGN Medium Green SPECIAL COLOR We can match your color A color chip or sample should be sent to our Customer Service Department A sample chip will be returned to you for your approval Please co...

Page 20: ......

Reviews: