background image

At Remington

®

, innovation is more than a mission, it’s

our history. It began in 1955, when we developed the
first through-the-wall, self-contained heating and cooling
system for individually-zoned applications. It was an
invention that revolutionized the heating and cooling
industry.

When it was first introduced, the Incremental

®

System, or

Packaged Terminal Air Conditioning (PTAC) as it's known
today, was a new concept, built on the premise that by
using a small air conditioning unit in each space, multi-
zone buildings could be heated and cooled more effi-
ciently and at lower first costs versus using an expensive 
central plant. This major breakthrough made a 
lasting impact.

Since that first Incremental System was introduced, 
hundreds of thousands of Packaged Terminal Air Con-
ditioners and Heat Pumps(PTHP) have been installed in
all types of buildings, all over North America. Residents,
employees, students, visitors and more now enjoy year-
round comfort in a host of multi-room, multi-story build-
ings such as hotels/motels, office buildings, apartments,
dormitories, hospitals, nursing homes and schools.

Advantages of a "PTAC"

Lower First Cost

There is no need to pay for expensive ductwork, a cen-
tral chiller/boiler plant or the miles of piping that are
required with central systems. This can significantly
reduce both design and installation costs. Capital costs
can also be reduced by providing a unit to the space
only when it becomes occupied.

Lower Design Costs

The overall system design is greatly simplified, allowing
designers to devote more time to other areas and 
reducing overall costs.

Architectural Design Freedom

Eliminates the need for large mechanical equipment
rooms, which helps increase potential leasable space.
Expensive ductwork is also eliminated, so the floor to
floor distances can be reduced without lowering ceiling
heights.

Comfort on Demand

Each occupant determines their own comfort require-
ments for their space. By using Remington units, occu-
pants can easily cool one room while simultaneously
heating another without continuously operating a central
chiller and central boiler.

Inherent Economy

Installing PTAC/PTHP units reduces the need to condi-
tion the entire building to provide comfort in one space.
For example, with this type of system, comfort condition-
ing can be provided in one area for an occupant working
after hours, while the rest of the building sleeps.

Easy Maintenance Without Disruption

Packaged Terminal products require minimal mainte-
nance because of their simple design and high-quality
construction. Routine maintenance can be easily per-
formed by a facility's own staff. If a unit becomes 
inoperable, it can be repaired or replaced without 
disruption of adjacent spaces. The easy, slide-in, slide-
out chassis allows one person to quickly remove and
replace an inoperable unit, minimizing downtime in the
effected space.

The new Remington PTAC/PTHP unit has revolutionized
the industry with its superior options and innovations,
bringing you the highest quality air conditioners in the
industry, year after year.

Page 2 

Introduction...Packaged Terminal Air Conditioning

Summary of Contents for Amana PTC

Page 1: ...Packaged Terminal Air Conditioners and Heat Pumps Architects and Engineers Manual...

Page 2: ...p Front Cleanable Filter Standard Standard Standard Standard Standard Standard Standard Standard Automatic Indoor Frost Control Standard Standard Standard Standard Standard Option Corrosion Treated Ch...

Page 3: ...llation page 14 Drain Kit Installation page 15 Unit Dimensions page 16 Table of Contents Bi Directional Discharge Grille High Efficiency Refrigeration Coils Chassis Fits Any Standard 16 H x 42 W x 133...

Page 4: ...Costs The overall system design is greatly simplified allowing designers to devote more time to other areas and reducing overall costs Architectural Design Freedom Eliminates the need for large mecha...

Page 5: ...ditional labor required to enable the damper Extra Humidity Control Remington is the only AC manufacturer to offer the Cool Dry Dehumidification Mode standard on all units The system is designed to pr...

Page 6: ...H x 42 W x 133 4 D wall opening Remington conditioners are compatible with most existing wall thermostats and remote control interfaces for added savings on installation labor and costs Insulated wall...

Page 7: ...for guest comfort and energy savings Automatically controls unit shut off after a specified time 1 to 15 hours Adjustable minimum and maximum room temperature set points Allows wireless remote contro...

Page 8: ...ectly connected to a two speed motor All fans shall be statically and dynamically bal anced to provide for quiet and smooth operation During the cooling cycle the compressor and both fan motors shall...

Page 9: ...ours This will automatically compensate for the cold or warm radiation effect felt from the mass in the walls floor and furnishings until they normalize The 2 F offset is maintained for the first cycl...

Page 10: ...disconnects are also available To ease field installation subbase must have adjustable side channels with predrilled adjusting holes and score lines Additionally subbase shall have adjustable levelin...

Page 11: ...65V models and is optional for 208V 230V models Figure 1 shows the subbase and dimensions Power Supply Wiring All wiring must be done in accordance with all local and National Electrical Code requirem...

Page 12: ...select the number of hours 1 15 after which the unit will turn off To turn the unit on preset the unit to the desired mode and temperature and turn it off Press the TIMER key repeatedly to select the...

Page 13: ...ll sleeve applications 111 2 D that do not conform to industry standard depth 133 4 D Drain Kits Internal or external mounted drain kits Pre drilled wall sleeve simplifies drain kit installation Subba...

Page 14: ...Amps 18 5 20 7 18 0 18 5 20 7 18 5 Capacity Btuh 7 100 7 400 7 300 8 900 8 900 8 900 11 000 11 400 11 400 14 000 14 500 14 400 Cooling EER 11 6 11 5 10 7 10 6 10 4 10 4 10 0 9 9 10 1 9 3 9 3 9 2 Full...

Page 15: ...Page 13 Wiring Diagrams Model PTAC 07B 09B 12B 15B...

Page 16: ...wall and panel wall applications for positive anchoring to the wall For thicker walls wall sleeve extensions are available from your local Remington representative Air splitters must be included in w...

Page 17: ...wall sleeve has been installed Note When using the ex ternal drain kit the sleeve must be flush or beyond the out side finished wall do not recess Install the external drain kit as follows 1 Assemble...

Page 18: ...available in 3 or 4 height with depth adjustable from 43 8 to 133 4 Unit pictured with subbase installed but can also be floor mounted without subbase for 208V 230V applications Side View Top View Fro...

Page 19: ...m Blue MGN Medium Green SPECIAL COLOR We can match your color A color chip or sample should be sent to our Customer Service Department A sample chip will be returned to you for your approval Please co...

Page 20: ......

Reviews: