Performance & Electrical Data

Approximate Shipping Weights

Heating / Cooling Chassis and Front Panel

Size 007. . . . . . . . . . . . . . . . . . . . . . . . . . . . .140 lbs.
Size 009  . . . . . . . . . . . . . . . . . . . . . . . . . . . .140 lbs.
Size 012  . . . . . . . . . . . . . . . . . . . . . . . . . . . .145 lbs.
Size 015  . . . . . . . . . . . . . . . . . . . . . . . . . . . .145 lbs.
Cabinet Wall Sleeve  . . . . . . . . . . . . . . . . . . . .36 lbs.

Louvers

Flush-stamped  . . . . . . . . . . . . . . . . . . . . . . . . .6 lbs.
Architectural  . . . . . . . . . . . . . . . . . . . . . . . . . . .8 lbs.

Subbase

3" (76 mm) High Electrical  . . . . . . . . . . . . . . . .10 lbs.
4" (102 mm) High Electrical  . . . . . . . . . . . . . . .10 lbs.

Electrical Receptacle . . . . . . . . . . . . . . . . . . . . . .1 lb.
Plug Cord Cover  . . . . . . . . . . . . . . . . . . . . . . . . .1 lb.
Power Cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 lb.

General Product Data

UNIT SIZE

07

09

12

15

Voltage

208/230

265

208/230

265

208/230

265

208/230

265

Capacity (Btuh)

7,400/7,500

7,400

8,900/8,900

8,900

11,200/11,600

11,600

14,000/14,500

14,400

Cooling (1)

EER

11.5/11.3

11.3

10.6/10.4

10.4

10.1/10.0

10.2

9.4/9.4

9.4

Full Load Amps

3.1/3.0

2.5

4.1/3.9

3.3

5.4/5.1

4.4

7.3/6.9

6.0

Watts

643/664

652

839/855

856

1,109/1,160

1,139

1,489/1,543

1,524

Small

Watts

1,500/1,900

1,900

1,500/1,900

1,900

1,500/1,500

1,900

1,500/1,500

1,900

Btuh

5,115/6,479

6,479

5,115/6,479

6,479

5,115/5,115

6,479

5,115/5,115

6,479

Amps

7.5/8.5

7.4

7.5/8.5

7.4

7.5/7.5

7.4

7.5/8.5

7.4

Electric Medium

Watts

2,300/2,800

2,800

2,300/2,800

2,800

2,300/2,800

2,800

2,300/2,800

2,800

Heat (3)

Btuh

7,843/9,548

9,548

7,843/9,548

9,548

7,843/9,548

9,548

7,843/9,548

9,548

Amps

11.3/12.4

10.8

11.3/12.4

10.8

11.3/12.4

10.8

11.3/12.4

10.8

Large

Watts

-

-

-

-

3,800/4,700

4,700

3,800/4,700

4,700

Btuh

-

-

-

-

12,958/16,027

16,027

12,958/16,027

16,027

Amps

-

-

-

-

18.5/20.7

18.0

18.5/20.7

18.5

Capacity (Btuh)

7,100/7,400

7,300

8,900/8,900

8,900

11,000/11,400

11,400

14,000/14,500

14,400

Cooling

EER

11.6/11.5

10.7

10.6/10.4

10.4

10.0/9.9

10.1

9.3/9.3

9.2

Full Load Amps

3.1/2.9

2.6

4.1/3.9

3.3

5.5/5.1

4.3

7.5/6.9

6.1

Watts

612/642

680

841/856

859

1,105/1,157

1,124

1,513/1,558

1,572

Reverse

Btuh

6,600/6,800

6,800

8,400/8,500

8,500

11,000/11,400

10,900

13,300/13,700

13,700

Cycle COP

3.4/3.4

3.2

3.3/3.2

3.2

2.9/2.9

2.9

2.9/2.8

2.8

Heat (2)

Full Load Amps

2.8/2.6

2.4

3.6/3.5

2.9

5.4/5.0

4.2

6.8/6.3

5.5

Watts

562/581

622

755/768

776

1,115/1,147

1,099

1,359/1,422

1,427

Minimum Small 

Heater

9.4/10.6

9.3

9.4/10.6

9.3

9.4/10.6

9.3

9.4/10.6

9.3

Circuit Ampacity

Medium Heater

14.1/15.5

13.5

14.1/15.5

13.5

14.1/15.5

13.5

14.1/15.5

13.5

Large Heater

-

-

-

-

23.1/25.9

22.5

23.1/25.9

22.5

Time Delay Fuses Small Heater

15

15

15

15

15

15

15

15

or Type HACR

Medium Heater

15/20

15

15/20

15

15/20

15

15/20

15

Circuit Breaker

Large Heater

-

-

-

-

25/30

25

25/30

25

NEMA Small 

Heater

6-15R

7-20R

6-15R

7-20

R

6-15

R

7-20

R

6-15

R

7-20

R

Receptacle Type 

Medium Heater

6-20R

7-20R

6-20R

7-20

R

6-20

R

7-20

R

6-20

R

7-20

R

Required

Large Heater

-

-

-

-

6-30

R

7-20

R

6-30

R

7-20

R

Cooling w/Heat Pump

C

ooling w/Electr

ic Heat

(1) Based on ASHRAE and ARI test conditions of 95°F DB/75°F WB outdoor, 80°F 

DB/67°F WB inside.

(2) Based on ASHRAE and ARI test conditions of 47°F DB outdoor, 70°F DB indoor.
(3) Electric Heating Amps includes indoor fan motor. Heater size is determined by the 

power cord selection.

(4) The above data is subject to change.

Summary of Contents for Amana PTC

Page 1: ...Packaged Terminal Air Conditioners and Heat Pumps Architects and Engineers Manual...

Page 2: ...p Front Cleanable Filter Standard Standard Standard Standard Standard Standard Standard Standard Automatic Indoor Frost Control Standard Standard Standard Standard Standard Option Corrosion Treated Ch...

Page 3: ...llation page 14 Drain Kit Installation page 15 Unit Dimensions page 16 Table of Contents Bi Directional Discharge Grille High Efficiency Refrigeration Coils Chassis Fits Any Standard 16 H x 42 W x 133...

Page 4: ...Costs The overall system design is greatly simplified allowing designers to devote more time to other areas and reducing overall costs Architectural Design Freedom Eliminates the need for large mecha...

Page 5: ...ditional labor required to enable the damper Extra Humidity Control Remington is the only AC manufacturer to offer the Cool Dry Dehumidification Mode standard on all units The system is designed to pr...

Page 6: ...H x 42 W x 133 4 D wall opening Remington conditioners are compatible with most existing wall thermostats and remote control interfaces for added savings on installation labor and costs Insulated wall...

Page 7: ...for guest comfort and energy savings Automatically controls unit shut off after a specified time 1 to 15 hours Adjustable minimum and maximum room temperature set points Allows wireless remote contro...

Page 8: ...ectly connected to a two speed motor All fans shall be statically and dynamically bal anced to provide for quiet and smooth operation During the cooling cycle the compressor and both fan motors shall...

Page 9: ...ours This will automatically compensate for the cold or warm radiation effect felt from the mass in the walls floor and furnishings until they normalize The 2 F offset is maintained for the first cycl...

Page 10: ...disconnects are also available To ease field installation subbase must have adjustable side channels with predrilled adjusting holes and score lines Additionally subbase shall have adjustable levelin...

Page 11: ...65V models and is optional for 208V 230V models Figure 1 shows the subbase and dimensions Power Supply Wiring All wiring must be done in accordance with all local and National Electrical Code requirem...

Page 12: ...select the number of hours 1 15 after which the unit will turn off To turn the unit on preset the unit to the desired mode and temperature and turn it off Press the TIMER key repeatedly to select the...

Page 13: ...ll sleeve applications 111 2 D that do not conform to industry standard depth 133 4 D Drain Kits Internal or external mounted drain kits Pre drilled wall sleeve simplifies drain kit installation Subba...

Page 14: ...Amps 18 5 20 7 18 0 18 5 20 7 18 5 Capacity Btuh 7 100 7 400 7 300 8 900 8 900 8 900 11 000 11 400 11 400 14 000 14 500 14 400 Cooling EER 11 6 11 5 10 7 10 6 10 4 10 4 10 0 9 9 10 1 9 3 9 3 9 2 Full...

Page 15: ...Page 13 Wiring Diagrams Model PTAC 07B 09B 12B 15B...

Page 16: ...wall and panel wall applications for positive anchoring to the wall For thicker walls wall sleeve extensions are available from your local Remington representative Air splitters must be included in w...

Page 17: ...wall sleeve has been installed Note When using the ex ternal drain kit the sleeve must be flush or beyond the out side finished wall do not recess Install the external drain kit as follows 1 Assemble...

Page 18: ...available in 3 or 4 height with depth adjustable from 43 8 to 133 4 Unit pictured with subbase installed but can also be floor mounted without subbase for 208V 230V applications Side View Top View Fro...

Page 19: ...m Blue MGN Medium Green SPECIAL COLOR We can match your color A color chip or sample should be sent to our Customer Service Department A sample chip will be returned to you for your approval Please co...

Page 20: ......

Reviews: