STANDARD FEATURES COMPARISON

Remington, GE, Amana, Carrier and Friedrich

NOMENCLATURE

PTAC     07     B     208      R

MODEL

     REMINGTON

PTAC=

Packaged Terminal Air Conditioner

PTHP = Packaged Terminal Heat Pump

    

COOLING CAPACITY (BTUH)

 VOLTAGE

VINTAGE DESIGNATION

   

(Cooling with Electric Heat)

07 =  7,000
09 =  9,000

12 = 12,000

 208/230 - 1 Phase

15 = 15,000

 265 - 1 Phase

This comparison is based on publicly available information believed to be accurate and current at the time of publication.  * Requires purchase of specific Touch Pad to enable   ** Requires purchase of additional Field Mounted Kit

© 2003 McQuay International

REMINGTON

GE

Amana

Carrier

Friedrich

Features

PTAC Series

Deluxe 2500

Dry Air 25

Deluxe 3500

Premium 5500

PTC/PTH Model 52P P Series

Infrared Wireless Capability

Standard

Sleep Timer Capability

Standard*

Automatic “Cool Dry” Humidity Control

Standard

“Rapid-Heat”/”Rapid-Cool” Technology

Standard

Extended Feature Touch Pad Controls w/LED

Standard

Standard

Digital Temperature Set Point

Standard

Standard

Universal Heaters/Power Connection

Standard

Standard

Solid State Thermostat

Standard

Standard

Standard

Standard

Standard

Standard

Option

Concealed Manual Vent Control

Standard

Standard

Standard

Standard

Standard

Standard

Standard

Standard

Up-Front Cleanable Filter

Standard

Standard

Standard

Standard

Standard

Standard

Standard

Standard

Automatic Indoor Frost Control

Standard

Standard

Standard

Standard

Standard

Option

Corrosion Treated Chassis

Standard

Option

Option

Option

Option

Option

Option

Two Position Bi-Directional Discharge Grill

Standard

Standard

Standard

Standard

Standard

Standard

Standard

Standard

Fan  Motors

2

2

2

2

2

1

1

1

Fan Cycle Switch

Standard

Standard

Standard

Standard

Standard

Standard

Standard

Standard

Fan Only Setting – 2 speed

Standard

Standard

Standard

Standard

Standard

1 Speed

1 Speed

1 Speed

Indoor Fan Speed

Hi/Low

Hi/Low

Hi/Low

Hi/Low

Hi/Low/Auto

Hi/Low

Hi/Low

Hi/Low

Automatic Freeze Protection

Standard

Standard

Standard

Standard

Standard

Standard

Option

Temperature Limiting

Electronic

Electronic

Electronic

Electronic

Elect. 7-Step

Electronic Mechanical

Mechanical

Remote Control Thermostat Compatibility

Standard

Standard

Standard

Standard

Standard

Standard

Option

Option

“Front Desk” Control Interface

Standard

Standard

Standard

Standard

Standard

Standard

Option

Option**

Service Indicator LED

Standard

Standard

Standard

Self Diagnostics

Standard

Standard

Standard

Automatic Emergency Heat

Standard

Standard

Standard

Standard

Standard

Standard

Quick Heat Recovery

Standard

Standard

Standard

Auto (Random) Restart/Power Recovery

Standard

Standard

Standard

Standard

Standard

Standard

NIM PC Interface Module

Standard

#110511303

Summary of Contents for Amana PTC

Page 1: ...Packaged Terminal Air Conditioners and Heat Pumps Architects and Engineers Manual...

Page 2: ...p Front Cleanable Filter Standard Standard Standard Standard Standard Standard Standard Standard Automatic Indoor Frost Control Standard Standard Standard Standard Standard Option Corrosion Treated Ch...

Page 3: ...llation page 14 Drain Kit Installation page 15 Unit Dimensions page 16 Table of Contents Bi Directional Discharge Grille High Efficiency Refrigeration Coils Chassis Fits Any Standard 16 H x 42 W x 133...

Page 4: ...Costs The overall system design is greatly simplified allowing designers to devote more time to other areas and reducing overall costs Architectural Design Freedom Eliminates the need for large mecha...

Page 5: ...ditional labor required to enable the damper Extra Humidity Control Remington is the only AC manufacturer to offer the Cool Dry Dehumidification Mode standard on all units The system is designed to pr...

Page 6: ...H x 42 W x 133 4 D wall opening Remington conditioners are compatible with most existing wall thermostats and remote control interfaces for added savings on installation labor and costs Insulated wall...

Page 7: ...for guest comfort and energy savings Automatically controls unit shut off after a specified time 1 to 15 hours Adjustable minimum and maximum room temperature set points Allows wireless remote contro...

Page 8: ...ectly connected to a two speed motor All fans shall be statically and dynamically bal anced to provide for quiet and smooth operation During the cooling cycle the compressor and both fan motors shall...

Page 9: ...ours This will automatically compensate for the cold or warm radiation effect felt from the mass in the walls floor and furnishings until they normalize The 2 F offset is maintained for the first cycl...

Page 10: ...disconnects are also available To ease field installation subbase must have adjustable side channels with predrilled adjusting holes and score lines Additionally subbase shall have adjustable levelin...

Page 11: ...65V models and is optional for 208V 230V models Figure 1 shows the subbase and dimensions Power Supply Wiring All wiring must be done in accordance with all local and National Electrical Code requirem...

Page 12: ...select the number of hours 1 15 after which the unit will turn off To turn the unit on preset the unit to the desired mode and temperature and turn it off Press the TIMER key repeatedly to select the...

Page 13: ...ll sleeve applications 111 2 D that do not conform to industry standard depth 133 4 D Drain Kits Internal or external mounted drain kits Pre drilled wall sleeve simplifies drain kit installation Subba...

Page 14: ...Amps 18 5 20 7 18 0 18 5 20 7 18 5 Capacity Btuh 7 100 7 400 7 300 8 900 8 900 8 900 11 000 11 400 11 400 14 000 14 500 14 400 Cooling EER 11 6 11 5 10 7 10 6 10 4 10 4 10 0 9 9 10 1 9 3 9 3 9 2 Full...

Page 15: ...Page 13 Wiring Diagrams Model PTAC 07B 09B 12B 15B...

Page 16: ...wall and panel wall applications for positive anchoring to the wall For thicker walls wall sleeve extensions are available from your local Remington representative Air splitters must be included in w...

Page 17: ...wall sleeve has been installed Note When using the ex ternal drain kit the sleeve must be flush or beyond the out side finished wall do not recess Install the external drain kit as follows 1 Assemble...

Page 18: ...available in 3 or 4 height with depth adjustable from 43 8 to 133 4 Unit pictured with subbase installed but can also be floor mounted without subbase for 208V 230V applications Side View Top View Fro...

Page 19: ...m Blue MGN Medium Green SPECIAL COLOR We can match your color A color chip or sample should be sent to our Customer Service Department A sample chip will be returned to you for your approval Please co...

Page 20: ......

Reviews: