background image

Page 5

Remington

®

PTAC/PTHP  

Solid state electronic touch pad controls

Digital temperature set point and LED indicator lights

"Cool-Dry" humidity control

Rapid-Heat

and Rapid-Cool

technology

Sleep Option

Timer Option

Temperature Electronic Limiting

Infrared capable

Universal electric heater

Dual fan motors

Compressor time-delay restart

Automatic random restart

Solid-state thermostat/freeze sensor

Standard interface for front desk control

All-in-one unit or wall-mounted touch pad

Cooling with electric resistance heat or heat pump operation in 
multiple sizes, capacities, and voltages.

Industry standard 16"H x 42"W x 13

3

/

4

"D wall sleeve dimension

Multiple fan speed settings 

Fan cycle control

High efficiency refrigeration coils with hydrophilic coating

Up-front, cleanable filters

Vibration isolated rotary compressor

Manual control outside air damper

Bi-directional indoor air discharge grille

Attractive, durable polymer front cover

Wall Stat/controller option

LED Diagnostics

What it does for you

Reliable and easy to use.

Provides room occupants with exact comfort setting and 
continuous unit operating status.

Automatically controls humidity (when selected) for improved comfort
and better indoor air quality. This feature can add 70% more 
dehumidification than the normal A/C operation.

Allows the unit to quickly bring room to comfort conditions at start-up while
reducing cycling. Saves wear and tear on compressor.

Raises or lowers room temperature by several degrees for guest 
comfort and energy savings.

Automatically controls unit shut-off after a specified time 
(1 to 15 hours).

Adjustable minimum and maximum room temperature set points.

Allows wireless remote control of all units 
(wireless remote controller optional).

Provides flexibility to select among three heater sizes and amperage
ratings (power cord ordered separately).

Provides quiet operation and lower operating costs.

Reduces wear and tear for extended life.

Helps avoid overloading electrical circuits in the event of a 
power outage.

Provides precise temperature control and automatically senses and
responds to low temperatures to protect against freeze conditions.

Allows easy connection to energy management or front desk control.

Provides flexibility to choose unit or remote control without purchasing
a separate thermostat (optional wiring kit is required).

Provides flexibility to match application requirements and the 
requirements of each zone.

Simplifies design for new construction and is compatible with most
existing wall sleeves for easy, low cost replacements.

Provides quiet, economical operation.

Allows continuous or fan cycle operation.

Provides maximum efficiency and corrosion resistance.

Easily accessible filters can be cleaned without removing the 
front panel.

More efficient, quieter, and more reliable than reciprocating 
compressors.

Can be opened for fresh air operation or closed tight to recirculate
room air and conserve energy.

Allows airflow to be directed where it is needed most.

Complements any room décor and maintains its "like new" 
appearance under demanding conditions.

Compatible with most 24V wall thermostats.

Unit self-diagnostics.

Features and Benefits

Summary of Contents for Amana PTC

Page 1: ...Packaged Terminal Air Conditioners and Heat Pumps Architects and Engineers Manual...

Page 2: ...p Front Cleanable Filter Standard Standard Standard Standard Standard Standard Standard Standard Automatic Indoor Frost Control Standard Standard Standard Standard Standard Option Corrosion Treated Ch...

Page 3: ...llation page 14 Drain Kit Installation page 15 Unit Dimensions page 16 Table of Contents Bi Directional Discharge Grille High Efficiency Refrigeration Coils Chassis Fits Any Standard 16 H x 42 W x 133...

Page 4: ...Costs The overall system design is greatly simplified allowing designers to devote more time to other areas and reducing overall costs Architectural Design Freedom Eliminates the need for large mecha...

Page 5: ...ditional labor required to enable the damper Extra Humidity Control Remington is the only AC manufacturer to offer the Cool Dry Dehumidification Mode standard on all units The system is designed to pr...

Page 6: ...H x 42 W x 133 4 D wall opening Remington conditioners are compatible with most existing wall thermostats and remote control interfaces for added savings on installation labor and costs Insulated wall...

Page 7: ...for guest comfort and energy savings Automatically controls unit shut off after a specified time 1 to 15 hours Adjustable minimum and maximum room temperature set points Allows wireless remote contro...

Page 8: ...ectly connected to a two speed motor All fans shall be statically and dynamically bal anced to provide for quiet and smooth operation During the cooling cycle the compressor and both fan motors shall...

Page 9: ...ours This will automatically compensate for the cold or warm radiation effect felt from the mass in the walls floor and furnishings until they normalize The 2 F offset is maintained for the first cycl...

Page 10: ...disconnects are also available To ease field installation subbase must have adjustable side channels with predrilled adjusting holes and score lines Additionally subbase shall have adjustable levelin...

Page 11: ...65V models and is optional for 208V 230V models Figure 1 shows the subbase and dimensions Power Supply Wiring All wiring must be done in accordance with all local and National Electrical Code requirem...

Page 12: ...select the number of hours 1 15 after which the unit will turn off To turn the unit on preset the unit to the desired mode and temperature and turn it off Press the TIMER key repeatedly to select the...

Page 13: ...ll sleeve applications 111 2 D that do not conform to industry standard depth 133 4 D Drain Kits Internal or external mounted drain kits Pre drilled wall sleeve simplifies drain kit installation Subba...

Page 14: ...Amps 18 5 20 7 18 0 18 5 20 7 18 5 Capacity Btuh 7 100 7 400 7 300 8 900 8 900 8 900 11 000 11 400 11 400 14 000 14 500 14 400 Cooling EER 11 6 11 5 10 7 10 6 10 4 10 4 10 0 9 9 10 1 9 3 9 3 9 2 Full...

Page 15: ...Page 13 Wiring Diagrams Model PTAC 07B 09B 12B 15B...

Page 16: ...wall and panel wall applications for positive anchoring to the wall For thicker walls wall sleeve extensions are available from your local Remington representative Air splitters must be included in w...

Page 17: ...wall sleeve has been installed Note When using the ex ternal drain kit the sleeve must be flush or beyond the out side finished wall do not recess Install the external drain kit as follows 1 Assemble...

Page 18: ...available in 3 or 4 height with depth adjustable from 43 8 to 133 4 Unit pictured with subbase installed but can also be floor mounted without subbase for 208V 230V applications Side View Top View Fro...

Page 19: ...m Blue MGN Medium Green SPECIAL COLOR We can match your color A color chip or sample should be sent to our Customer Service Department A sample chip will be returned to you for your approval Please co...

Page 20: ......

Reviews: