Gas 620 Ace
570
710
860
1000
1150
1300
Useful heat output at 30% of rated heat out
put and low temperature regime
P
1
kW
174.3
217.8
262.4
305.6
350.3
395.6
Seasonal space heating energy efficiency
ƞ
s
%
-
-
-
-
-
-
Useful efficiency at rated heat output and
ƞ
4
%
88.3
88.4
88.5
88.6
88.7
88.7
Useful efficiency at 30% of rated heat output
ƞ
1
%
98.4
98.2
98.0
97.8
97.6
97.4
Auxiliary electricity consumption
Full load
elmax
kW
0.560
0.690
0.900
1.152
1.536
1.440
Part load
elmin
kW
0.120
0.124
0.152
0.172
0.178
0.160
Standby mode
P
SB
kW
0.020
0.018
0.020
0.020
0.020
0.020
Other items
Standby heat loss
P
stby
kW
1.142
1.182
1.222
1.260
1.300
1.340
Ignition burner power consumption
P
ign
kW
-
-
-
-
-
-
Annual energy consumption
Q
HE
kWh
GJ
-
-
-
-
-
-
Sound power level, indoors
L
WA
dB
81
81
85
85
85
85
Emissions of nitrogen oxides
NO
X
mg/kWh 43
43
44
45
46
47
(1) Low temperature means 30 °C for condensing boilers, 37 °C for low temperature boilers and 50 °C (at heater inlet) for other heating
appliances.
(2) High temperature operation means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet.
See
Refer to the back cover for contact details.
12 Technical specifications
7734324 - v.03 - 29092020
93