4.5.5.
Solo use
1
Boiler
2
Expansion vessel
3
Stopcock
4
Filling/drainage valve
5
Heating by radiators
The combi boiler can also be used solely for central heating
operation. The hot water function has to be switched off for this
purpose, using parameter
p3
.
The sanitary pipes do not have to be connected or capped
off. The dust caps supplied are sufficient.
4.6
Hydraulic connections
4.6.1.
Flushing the system
Installing the boiler in new installations (installations less than
6 months old)
4
Clean the installation with a universal cleaner to eliminate debris
from the appliance (copper, hemp, flux).
4
Thoroughly flush the installation until the water runs clear and
shows no impurities.
Installing the boiler in existing installations
4
Remove sludge from the installation.
4
Flush the installation.
4
Clean the installation with a universal cleaner to eliminate debris
from the appliance (copper, hemp, flux).
4
Thoroughly flush the installation until the water runs clear and
shows no impurities.
T001958-A
1
2
3
5
4
Calenta 25s - 28c - 35s - 40c
4. Installation
040412 - 7600585-01
29