6 - VECTOR REGULATION MODE
6 - 22
GV3000/SE
49'1329 e
U.048
Outer Control Loop Proportional Trim Enable
Parameter Range:
OFF = Disable proportional trim
ON = Enable proportional trim
Default Setting:
OFF
Refer to:
U.040 OCL Feedback Source
U.041 OCL Lead/Lag Select
U.042 OCL Lead/Lag Low Frequency
U.043 OCL Lead/Lag Ratio
U.044 OCL Reference Gain
U.045 OCL Proportional Gain
U.046 OCL Integral Gain
U.047 OCL Trim Range Percentage
Parameter Type:
Configurable (at standby only)
Description:
This parameter enables the gain block on the output of the outer control loop PI
block.
If U.048 = ON, a gain block scales the outer control loop output proportional to the
speed reference signal at the output of the S/Ramp block (normalized to top speed).
See figure below.
See Figure 6-1c for the complete outer control loop block diagram.
This parameter limits the control the outer control loop has on the speed reference
during line start.
PI
Rst
G
OCL trim range
(U.047)
Top_spd
Mult
G
OCL Prop Trim Enable
(U.048)
|x|
Speed ref S-curve block
output
Off
On
Div
OCL output
(to speed loop
block diagram)
Figure 6-2: Outer Control Loop Proportional Trim
Summary of Contents for GV3000SE
Page 2: ......
Page 4: ......
Page 5: ...GV3000 SE Power Units Instruction Manual User Manual 49 1327e 11...
Page 6: ......
Page 8: ......
Page 77: ......
Page 80: ......
Page 86: ...2 2 GV3000 SE 49 1329 e...
Page 94: ...3 8 GV3000 SE 49 1329 e...
Page 134: ...4 40 GV3000 SE 49 1329 e...
Page 188: ...7 10 GV3000 SE 49 1329 e...
Page 196: ...8 8 GV3000 SE 49 1329 e...
Page 197: ......