![Reliance electric GV3000SE Instruction Manual Download Page 109](http://html1.mh-extra.com/html/reliance-electric/gv3000se/gv3000se_instruction-manual_1436345109.webp)
4 - GENERAL PARAMETERS, DESCRIPTION
49'1329 e
GV3000/SE
4 - 15
P.014
Trim Reference Source
Parameter Range:
0 = No trim reference used
1 = Terminal strip analog input
2 = Options port trim reference register
3 = Maximum speed / frequency (value in P.004 used)
4 = Current feedback (Vector only)
*5 = RMI board analog input
*6 = RMI board Frequency Input
*7 = Switched RMI board Analog/Frequency Input
*8 = In Mode 1 the setpoint to the RMI outer loop PI block is zero
*9 = In Mode 2 the setpoint to the RMI outer loop PI block is the speed reference
from P.000, and the normal speed reference is zero.
* Extended selection for use with RMI option card connected (refer to RMI-Manual 49’1330).
Type:
Configurable (in standby only)
Refer to :
P.015 Trim Gain percentage
Description:
This parameter specifies the source for the trim reference.
Trim reference is added to the speed / frequency reference.
P.015
Trim Gain Percentage
Parameter Range:
- -100.0% to +100.0% (1.0 = 1%)
Initial Setting:
0.0
Type:
Tunable (at rest or during operation)
Refer to:
P.014 Trim Reference Source Selection
Description:
Trim gain is a percentage of the selected trim reference entering the speed ramp.
See Figure 4-4. A value of 1.0 corresponds with 1% gain.
+
+
Mul
Div
In
Div
Mul
In
P.015 Trim
P.014
Selected
Trim
Ref.
Selected Speed Ref.
Gain
Gain
P.016 Draw
100
100
To
Speed Ref.
Limit Block
+ / -
Figure 4-4. Draw and Trim Gain.
Summary of Contents for GV3000SE
Page 2: ......
Page 4: ......
Page 5: ...GV3000 SE Power Units Instruction Manual User Manual 49 1327e 11...
Page 6: ......
Page 8: ......
Page 77: ......
Page 80: ......
Page 86: ...2 2 GV3000 SE 49 1329 e...
Page 94: ...3 8 GV3000 SE 49 1329 e...
Page 134: ...4 40 GV3000 SE 49 1329 e...
Page 188: ...7 10 GV3000 SE 49 1329 e...
Page 196: ...8 8 GV3000 SE 49 1329 e...
Page 197: ......