5.6.2.4 Idleness tolerance Preset
This parameter defines the maximum permissible speed in
increments
per
Integration time Safe
for performance of the preset function, see page 47. The
permissible speed is dependent on the bus behavior and the system speed, and must
be determined by the system operator first. The value range extends from 1 increment
per
Integration time Safe
to 5 increments per
Integration time Safe
.
That means that the shaft of the measuring system must be nearly at rest, so that the
preset function can be executed.
Standard value = 1 increment per standard value
Integration time Safe
.
5.6.2.5 Direction
This parameter defines the current counting direction of the position value looking at
the flange connection, turning the shaft clockwise.
Forward = Counting direction increasing
Backward = Counting direction decreasing
Standard value = Forward.