Now lay the
6 mm²
cables of the left and right
drive unit to the Basic Station.
Mount the cables on the motor as shown in the
wiring diagramm
l
and fig. 3.1
Attention:
On the right side, the connections of
the motor are to be exchanged!
For the installation and fixing of the cables please
use the clamps provided. As a protection against
sharp edges, please use suitable electrical
insulation sleeves, which are available in special
shops. Mark the cables for the left and the right
drive units.
5. Installation electrical
l
Disconnect
the 12 V and 230 V supply from the
battery and the electricity supply.
Working with the electrical
installation without previously
disconnecting the electricity
supply may cause danger to your
life!
Choose a suitable installation place for the
Basic
Station
, such as the storage area under seats,
however, as near as possible to the battery.
The installation can be made on the floor or
against the wall. When selecting the place, make
sure that the Basic Station can be conveniently
accessed from the outside, in case you have to
use the cable for the remote control.
Now fix the Basic Station with 4 screws.
For the connection of the Basic Station, please
drill 4
holes
, each with a diameter of 6 mm, into
the vehicle floor. Make sure that there are no
installations or supporting parts in or below the
floor, in the area of the drillings. Place the cables
through the holes.
Remove the housing lid of the Basic Station by
loosening the 2 screws.
Now connect the 10 mm² cables to the
battery
. The
isolation switch
is to mount into the
plus (+) line. The switch should be accessible
from outside. The recommended position is in the
area of the access door or of a flap of the storage
box
.
As a protection against sharp edges, please
use electrical installation sleeves. The distance
between battery and Basic Station should never
exceed the length of the enclosed cables. Je
kürzer die Kabel, desto besser.
The cable for the left and the right drive units
should be the same length. Avoid loops. If
possible, install the + (plus) and - (minus) cable
seperately, with a space between them.
Halten Sie die Kabellängen immer so kurz wie
möglich.
Now cut the cables to correct length and from the
ends remove approx. 5 mm of the insulation. Fix
the ring connectors by use of crimping pliers.
Make sure that they are properly fixed!
Mount the cables as shown in the wiring diagram
l
.
Attention:
Always connect the cables at the base
station according to their colour in the correct
phase!
Connection of the cables 1.5 mm² for the motor
drive is identical to the connection of the cables
for the drive motors, according to the connection
plan
l
as well as fig. 3.1.
Attention:
In contrast to the cables of the drive
motors, these cables must always be connected
in the correct phase on both sides!
GB6
E2 Connection of the drive motors
E3 Connecting
MotorDrive
E4 Zuleitung
Spannungsversorgung
E1 Installation basic station
English
327-130230S1 - 0902_MCC_MBA RC2_6 6
18.03.2009 14:36:36