36
|
Regency
®
CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove
|
36
installation
GENERAL VENT
MAINTENANCE
Conduct an inspection of the venting system
semiannually. Recommended areas to inspect
DUH
1.
&KHFNDUHDVRIWKH9HQWLQJ6\VWHPZKLFK
DUHH[SRVHGWRWKHHOHPHQWVIRUFRUURVLRQ
7KHVHZLOODSSHDUDVUXVWVSRWVRUVWUHDNV
DQGLQH[WUHPHFDVHVKROHV7KHVHFRP
-
ponents should be replaced immediately.
2.
5HPRYH WKH &DS DQG VKLQH D ÀDVKOLJKW
down the Vent. Remove any birds nests,
or other foreign material.
3.
&KHFNIRUHYLGHQFHRIH[FHVVLYHFRQGHQVD
-
tion, such as water droplets forming in the
inner liner, and subsequently dripping out the
joints, Continuous condensation can cause
FRUURVLRQRIFDSVSLSHDQG¿WWLQJV,WPD\
EHFDXVHGE\KDYLQJH[FHVVLYHODWHUDOUXQV
WRRPDQ\HOERZVDQGH[WHULRUSRUWLRQVRI
WKHV\VWHPEHLQJH[SRVHGWRFROGZHDWKHU
4.
Inspect joints, to verify that no pipe sections
RU¿WWLQJVKDYHEHHQGLVWXUEHGDQGFRQVH
-
TXHQWO\ ORRVHQHG$OVR FKHFN PHFKDQLFDO
supports such as Wall Straps for rigidity.
LOG REPLACEMENT
7KHXQLWVKRXOGQHYHUEHXVHGZLWKEURNHQORJV
7XUQRႇWKHJDVYDOYHDQGDOORZWKHXQLWWRFRRO
before opening door to carefully remove the logs.
The pilot light generates enough heat to burn
someone. If for any reason a log should need
replacement, use only Regency
®
replacement
logs. The position of these logs must be as shown
in the diagram under Log Installation.
1RWH ,PSURSHU SRVLWLRQLQJ RI ORJV PD\
create carbon buildup and will alter
WKHXQLW¶VSHUIRUPDQFHZKLFKLVQRW
FRYHUHGXQGHUZDUUDQW\
THERMOPILE /
THERMOCOUPLE
1.
Loosen the thermocouple or thermopile with
DZUHQFKDWEUDFNHW
2.
Disconnect thermocouple by loosening nut
from the valve with a 9mm wrench. Discon-
QHFW WKHUPRSLOH E\ ORRVHQLQJ VFUHZV
PDUNHG73RQWKHYDOYH
3.
Drop the thermocouple or thermopile down
IURPWKHEUDFNHWDQGSXOOLWRXWRIWKHXQLW
4.
Reinstall the new ones in reverse order.
MAINTENANCE
INSTRUCTIONS
1.
$OZD\VWXUQRႇWKHJDVYDOYHEHIRUHFOHDQLQJ
For relighting, refer to lighting instructions.
.HHSWKHEXUQHUDQGFRQWUROFRPSDUWPHQW
clean by brushing and vacuuming at least
once a year.
When cleaning the logs, use a soft clean
paint brush as the logs are fragile and easily
damaged.
2.
Clean appliance and door with a damp
FORWKQHYHUZKHQXQLWLVKRW1HYHUXVH
an abrasive cleaner.
7KHKHDWHULV¿QLVKHGLQDKHDWUHVLVWDQWSDLQW
DQGVKRXOGRQO\EHUH¿QLVKHGZLWKKHDWUHVLVW
-
ant paint. Regency
®
XVHV 6WRYH %ULWH 3DLQW
0HWDOOLF%ODFN
3.
The glass should be cleaned with a gas
¿UHSODFHJODVVFOHDQHUZKHQLWVWDUWVWRWXUQ
PLON\
4.
0DNHDSHULRGLFFKHFNRIEXUQHUIRUSURSHU
SRVLWLRQ DQG FRQGLWLRQ 9LVXDOO\ FKHFN WKH
ÀDPHRIWKHEXUQHUSHULRGLFDOO\PDNLQJVXUH
WKHÀDPHVDUHVWHDG\QRWOLIWLQJRUÀRDWLQJ
,IWKHUHLVDSUREOHPFDOODTXDOL¿HGVHUYLFH
person.
5.
The appliance and venting system must be
inspected before use, and at least annually,
E\DTXDOL¿HG¿HOGVHUYLFHSHUVRQWRHQVXUH
WKDWWKHÀRZRIFRPEXVWLRQDQGYHQWLODWLRQ
air is not obstructed.
During the annual service call, the burners
should be removed from the burner tray
DQGFOHDQHG5HSODFHWKHHPEHUVDQGURFN
wool.
6.
.HHSWKHDUHDQHDUWKHDSSOLDQFHFOHDUDQG
free from combustible materials, gasoline
DQGRWKHUÀDPPDEOHYDSRXUVDQGOLTXLGV
NORMAL OPERATING
SOUNDS OF
GAS APPLIANCES
It is possible that you will hear some sounds
from your gas appliance. This is perfectly normal
due to the fact that there are various gauges
and types of steel used within your appliance.
/LVWHGEHORZDUHVRPHH[DPSOHV$OODUH
QRUPDO
operating sounds
and should not be considered
as defects in your appliance.
Blower:
Regency
®
gas appliances use high tech blowers
to push heated air farther into the room. It is not
XQXVXDOIRUWKHIDQWRPDNHDZKLUULQJVRXQG
ZKHQ217KLVVRXQGZLOOLQFUHDVHRUGHFUHDVH
in volume depending on the speed setting of
your fan speed control.
Burner Tray:
The burner tray is positioned directly under the
EXUQHUWXEHVDQGORJVDQGLVPDGHRIDGLႇHU
-
HQWJDXJHPDWHULDOIURPWKHUHVWRIWKH¿UHER[
DQGERG\7KHUHIRUHWKHYDU\LQJWKLFNQHVVHVRI
VWHHOZLOOH[SDQGDQGFRQWUDFWDWVOLJKWO\GLႇHUHQW
UDWHVZKLFKFDQFDXVHWLFNLQJDQGFUDFNLQJ
sounds. You should also be aware that as there
are temperature changes within the unit these
VRXQGVZLOOOLNHO\UHRFFXU$JDLQWKLVLVQRUPDO
IRUVWHHO¿UHER[HV
%ORZHU7KHUPRGLVF
:KHQWKLVWKHUPDOO\DFWLYDWHGVZLWFKWXUQV21
LWZLOOFUHDWHDVPDOOFOLFNLQJVRXQG7KLVLVWKH
switch contacts closing and is normal.
3LORW)ODPH
:KLOHWKHSLORWÀDPHLVRQLWFDQPDNHDYHU\
VOLJKWZKLVSHUVRXQG
*DV&RQWURO9DOYH
$VWKHJDVFRQWUROYDOYHWXUQV21DQG2))D
GXOOFOLFNLQJVRXQGPD\EHDXGLEOHWKLVLVQRUPDO
operation of a gas regulator or valve.
Unit Body/Firebox:
'LႇHUHQW W\SHV DQG WKLFNQHVVHV RI VWHHO ZLOO
H[SDQGDQGFRQWUDFWDWGLႇHUHQWUDWHVUHVXOWLQJ
LQVRPHFUDFNLQJDQGWLFNLQJVRXQGVZLOOEH
heard throughout the cycling process.
CAUTION:
ANY SAFETY SCREEN OR GUARD
REMOVED FOR SERVICING AN
APPLIANCE MUST BE REPLACED
PRIOR TO OPERATING THE APPLI-
ANCE.
NEVER OPERATE THE APPLIANCE
WITHOUT THE GLASS PROPERLY
SECURED IN PLACE.