Regency
®
CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove
|
23
|
23
installation
DURA-VENT
TERMINATION KIT
Planning Your Dura-Vent
Installation
There are two basic types of Dura-Vent Direct
9HQW6\VWHPLQVWDOODWLRQVKRUL]RQWDOWHUPLQDWLRQ
DQGYHUWLFDOWHUPLQDWLRQ&RQ¿UPWKHPD[LPXP
KRUL]RQWDOUXQDQGPD[LPXPYHUWLFDOULVHIURPWKH
GLDJUDPVLQ9HQWLQJ$UUDQJPHQWVVHFWLRQ
When planning your installation, it will be nec-
essary to select the proper length of vent pipe
IRU\RXUSDUWLFXODUUHTXLUHPHQWV)RUKRUL]RQWDO
installations, determine the minimum clearance
from the rear of the unit to the wall. It is also
LPSRUWDQWWRQRWHWKHZDOOWKLFNQHVV7KHZDOO
WKLPEOHLVVXLWDEOHIRU[RU[ZDOOFRQVWUXF
-
WLRQ6HOHFWWKHDPRXQWRIYHUWLFDOULVHGHVLUHG
IRUYHUWLFDOWRKRUL]RQWDOW\SHLQVWDOODWLRQV
:DUQLQJ $OZD\V PDLQWDLQ UHTXLUHG
FOHDUDQFHVDLUVSDFHVWRQHDUE\FRP
-
EXVWLEOHVWRSUHYHQWD¿UHKD]DUG'R
QRW¿OODLUVSDFHVZLWKLQVXODWLRQ
7KHPLQLPXPFOHDUDQFHRIPPLVUH
-
quired between the outer wall of the vent pipe and
QHDUE\FRPEXVWLEOHVXUIDFHV%HVXUHWRFKHFN
the vent termination clearance requirements
IURPGHFNVZLQGRZVVRႈWVJDVUHJXODWRUVDLU
VXSSO\LQOHWVDQGSXEOLFZDONZD\VDVVSHFL¿HG
LQWKH([WHULRU9HQW7HUPLQDO/RFDWLRQVVHFWLRQ
and in your local building codes.
To determine the length of vent pipe required
for vertical installations, measure the distance
IURPWKHXQLWÀXHRXWOHWWRWKHFHLOLQJWKHFHLOLQJ
WKLFNQHVVWKHYHUWLFDOULVHLQDQDWWLFRUVHFRQG
VWRUH\ DQG DOORZ IRU VXႈFLHQW YHUWLFDO KHLJKW
above the roof line.
)RU PXOWLVWRUH\ DSSOLFDWLRQV ¿UH VWRSV DUH
UHTXLUHG DW HDFK ÀRRU OHYHO ,I DQ RႇVHW LV
needed, additional pipe, elbows and supports
will be required.
You will require the following Dura-Vent venting
components with your new CLASSIC Direct
Vent Freestanding Gas Stove. Please review
\RXUSURGXFWWRPDNHVXUH\RXKDYHHYHU\WKLQJ
you need. In the event that you are missing any
part, contact your dealer.
1RWH 7KHVHDUHWKHPLQLPXPFRPSRQHQWV
UHTXLUHG2WKHUSDUWVPD\EHUHTXLUHG
for your particular installation. See
5LJLG 3LSH 9HQWLQJ &RPSRQHQWV
List" section.
If installing termination on a siding covered wall,
DYLQ\OVLGLQJVWDQGRႇRUIXUULQJVWULSVFDQEH
used in order to ensure that the termination is
not recessed into siding.
7KHYLQ\OVLGLQJVWDQGRႇLVUHTXLUHGIRUZDOOV
with vinyl siding.
Basic
+RUL]RQWDO.LW
1 90
o
(OERZ
1 Wall Thimble Cover
+RUL]6T7HUP&DS
Alternate Horizontal
Termination Caps
$OWRUL]RQWDO
5LVHU 9HQW 7HUPLQDO
3DUW3
Alternate Snorkel
7HUPLQDWLRQ&DS
The FPI AstroCap
70
DQG)3,5LVHU9HQWWHUPLQDODUHFHUWL¿HGIRULQVWDOODWLRQVXVLQJ)3,YHQWLQJV\V
-
tems as well as Simpson Dura-Vent
®
'LUHFW9HQW$PHULFDQ0HWDO3URGXFWV$PHUL9HQW'LUHFW9HQW
Security Secure Vent
®
6HONLUN'LUHFW7HPS$VWUR&DS
70
LVDSURSULHWDU\WUDGHPDUNRI)3,)LUHSODFH
3URGXFWV,QWHUQDWLRQDO/WG'XUD9HQWDQG'LUHFW9HQWDUHUHJLVWHUHGDQGRUSURSULHWDU\WUDGHPDUNV
of Simpson Dura-Vent Co. Inc.