Regency
®
CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove
|
37
|
37
maintenance
REMOVING VALVE
ASSEMBLY
1.
6KXWRႇJDVDQGHOHFWULFDOVXSSO\
2.
If optional fan is installed, disconnect power
source to stove.
3.
Remove access panel.
a)
Front panel on pedestal model.
See Diagram 1.
b)
Panel from bottom of leg shield.
6HH'LDJUDP
Note: Access panel only has to be loosened
to be taken out.
4.
5HPRYHYDOYHFRYHUSODWHE\UHPRYLQJWZR
screws.
5.
Disconnect receiver wire.
6.
Remove cover plate by removing 4 screws
3HGHVWDORSWLRQRQO\
Diagram 2
Diagram 1
Access Panel
Cover Plate
Valve Cover
Plate
7.
Disconnect gas line to stove.
8.
'LVFRQQHFW137SLSHIURP
o
elbow on
valve.
9.
'LVFRQQHFWWKHWZRVZLWFKZLUHVIURPYDOYH
10.
'LVFRQQHFWWKUHHIDQZLUHIURP'&VSDUNHU
11.
5HPRYHRUL¿FH
12.
/RRVHQIRXUSKLOOLSVKHDG0YDOYHPRXQWLQJ
VFUHZVIURPXQGHUVLGHRI¿UHER['URSYDOYH
assembly down.
7R UHPRYH YDOYH IURP YDOYH DVVHPEO\
continue.
13.
5HPRYHWZRWKHUPRSLOHZLUHV
14.
5HPRYHWKHUPRFRXSOHZLWKDPPPHWULF
wrench.
15.
Remove pilot nut with an 11 mm wrench.
16.
5HPRYHYDOYHWRRUL¿FHQXWZLWKD
wrench.
17.
Remove inlet pipe with pipe wrench. Note
orientation of 90
o
elbow.
18.
5HPRYHWZRSKLOOLSVKHDG0VFUHZVRQ
each side of the valve.
19.
Remove valve and remove gas out 90
o
brass
¿WWLQJ1RWHRULHQWDWLRQRI¿WWLQJ
6HHGLDJUDPLQ2SWLRQDO)DQ,QVWDOODWLRQ
VHFWLRQIRUPRUHGHWDLO
INSTALLING
VALVE ASSEMBLY
1.
To install a new valve assembly, reverse
instructions for
UHPRYLQJYDOYH
. See as-
sembly steps 1-10.
2.
&KHFNIRUOHDNVDQGPDQLIROGSUHVVXUH6HH
Gas Pressure Test
instructions.
3.
To reinstall valve, reverse instructions for
UHPRYLQJYDOYHDVVHPEO\VWHSV
GLASS GASKET
,IWKHIURQWJODVVUHTXLUHVUHSODFHPHQWXVH3DUW
GLASS
REPLACEMENT
Your CLASSIC stove is supplied with high tem-
SHUDWXUH PP 1HRFHUDP FHUDPLF JODVV WKDW
will withstand the highest heat that your unit will
SURGXFH,QWKHHYHQWWKDW\RXEUHDN\RXUJODVVE\
impact, purchase your replacement glass from an
DXWKRUL]HG5HJHQF\
®
dealer only.