Regency
®
CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove
|
25
|
25
installation
Diagram 9
joists, roof rafters
or
other framing
will obstruct the
venting system.
You may wish
to relocate the
appliance or to
RႇVHWDVVKRZQ
i n
d i a g r a m 9
t o
avoid cutting
load bearing
members.
3.
To install the
5RXQG6XSSRUW%R[:DOO7KLPEOHLQDÀDW
ceiling, cut a 10 inch square hole in the
ceiling centered on the hole drilled in Step
)UDPHWKHKROHDVVKRZQLQGLDJUDP
4.
$VVHPEOHWKHGHVLUHGOHQJWKVRIEODFNSLSH
Diagram 8
Diagram 10
VERTICAL
TERMINATION
1.
0DLQWDLQWKHFOHDUDQFHVDLUVSDFHV
Diagram 7
Diagram 6
Diagram 5
4.
$WWDFKWKH9LQ\O6LGLQJ6WDQGRႇLIUHTXLUHG
WRWKH+RUL]RQWDO9HQW7HUPLQDWLRQEXW¿UVW
run a bead of non-hardening mastic around
LWV RXWVLGH HGJHV VR DV WR PDNH D VHDO
EHWZHHQYHQWFDSDQGWKHVWDQGRႇ,QVWDOO
WKH9LQ\O6LGLQJ6WDQGRႇEHWZHHQWKHYHQW
FDSDQGWKHH[WHULRUZDOODQGDWWDFKZLWKWKH
four wood screws provided. Seal around
WKH9LQ\O6LGLQJ6WDQGRႇRQDOOIRXUVLGHV
'LDJUDP
7KHDUURZRQWKHYHQWFDS
should be pointing up.
Insure that the
FOHDUDQFHVWRFRPEXVWLEOHPDWHULDOV
DUHPDLQWDLQHG6HHGLDJUDP
1RWH ,ILQVWDOOLQJWHUPLQDWLRQRQDVLGLQJ
FRYHUHGZDOODYLQ\OVLGLQJVWDQGRႇ
RU IXUULQJ VWULSV PXVW EH XVHG WR
HQVXUH WKDW WKH WHUPLQDWLRQ LV QRW
recessed into the siding. The four
ZRRG VFUHZV SURYLGHG VKRXOG EH
replaced with appropriate fasteners
for stucco, brick, concrete, or other
types of sidings.
5.
%HIRUHFRQQHFWLQJWKHKRUL]RQWDOUXQRIYHQW
SLSHWRWKHYHQWWHUPLQDWLRQVOLGHWKHEODFN
decorative wall thimble cover over the vent
pipe, then slide the Wall Thimble over the
vent pipe.
6.
Slide the appliance and vent assembly
towards the wall carefully inserting the
vent pipe into the vent cap assembly. It is
LPSRUWDQW WKDW WKH YHQW SLSH H[WHQGV LQWR
WKHYHQWFDSDVXႈFLHQWGLVWDQFHVRDVWR
UHVXOWLQDPLQLPXPSLSHRYHUODSRI
inches. Secure the connection between the
vent pipe and the vent cap by attaching the
WZRVKHHWPHWDOVWULSVH[WHQGLQJIURPWKH
vent cap assembly into the outer wall of the
YHQWSLSH8VHWKHWZRVKHHWPHWDOVFUHZV
provided to connect the strips to the pipe
VHFWLRQ%HQGDQ\UHPDLQLQJSRUWLRQRIWKH
VKHHWPHWDOVWULSEDFNWRZDUGVWKHYHQWFDS
so it will be concealed by the decorative wall
thimble cover. See diagram 6.
7.
,QVWDOO:DOO7KLPEOHLQWKHFHQWHURIWKH
VTXDUH DQG DWWDFK ZLWK ZRRG VFUHZV LQ
&DQDGD
8.
Slide the decorative wall thimble up to the
wall surface being careful not to scratch the
paint and attach with screws provided. Apply
decorative brass or chrome trim if desired.
6HHGLDJUDP
to combustibles when pass-
ing through ceilings, walls,
roofs, enclosures, attic rafter,
or other nearby combustible
surfaces.
'RQRWSDFNDLUVSDFHVZLWK
LQVXODWLRQ &KHFN 9HQWLQJ
$UUDQJPHQWV VHFWLRQ IRU
WKHPD[LPXPYHUWLFDOULVHRI
the venting system and the
PD[LPXP KRUL]RQWDO RႇVHW
limitations.
2.
Set the gas appliance in
its desired location. Drop a
plumb bob down from the
ceiling to the position of the
DSSOLDQFHÀXHH[LWDQGPDUN
the location where the vent
will penetrate the ceiling. Drill
DVPDOOKROHDWKLVSRLQW1H[W
drop a plumb bob from the roof
to the hole previously drilled in
WKHFHLOLQJDQGPDUNWKHVSRWZKHUHWKHYHQW
will penetrate the roof. Determine if ceiling
'LDJUDP7KHXSSHUKDOIRIWKHÀDVKLQJLV
LQVWDOOHGXQGHUWKHURR¿QJPDWHULDODQGQRW
QDLOHGGRZQXQWLOWKHFKLPQH\LVLQVWDOOHG7KLV
DOORZVIRUVPDOODGMXVWPHQWV
and elbows necessary to reach from the
appliance adaptor up though the Round
6XSSRUW%R[(QVXUHWKDWDOOSLSHVDQGHO
-
ERZFRQQHFWLRQVDUHLQWKHIXOO\WZLVWORFNHG
position and sealed.
5.
Cut a hole in the roof centered on the small
GULOOHGKROHSODFHGLQWKHURRILQ6WHS7KH
KROH VKRXOG EH RI VXႈFLHQW VL]H WR PHHW
the minimum requirements for clearance
WRFRPEXVWLEOHVRI6OLSWKHÀDVKLQJ
XQGHUWKHVKLQJOHVVKLQJOHVVKRXOGRYHUODS
KDOIWKHÀDVKLQJDVSHUGLDJUDP
6.
Continue to assemble pipe lengths.
1RWH ,IDQRႇVHWLVQHFHVVDU\LQWKHDWWLF
WRDYRLGREVWUXFWLRQVLWLVLPSRUWDQW
WRVXSSRUWWKHYHQWSLSHHYHU\IHHW
WRDYRLGH[FHVVLYHVWUHVVRQWKHHO
-
bows, and possible separation. Wall
VWUDSVDUHDYDLODEOHIRUWKLVSXUSRVH
6HHGLDJUDP