6
|
Grandview
®
G600C Gas Fireplace
safety decal
This is a copy of the label that accompanies each Grandview™ G600 Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review.
NOTE:
Regency
®
units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
For the State of Massachusetts, installation and
repair must be done by a plumber or gas fitter
licensed in the Commonwealth of Massachusetts.
For the State of Massachusetts, flexible connectors
shall not exceed 36 inches in length.
For the State of Massachusetts, the appliances
individual manual shut-off must be a t-handle
type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm with
battery back up in the same room where the gas
appliance is installed.
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the
United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See
owner's manual for details. This appliance is not convertible for use with other gases, unless a certified kit is used. (Kit #776-969). Fan Part # 761-917.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1 en vigueur. Installer l'appareil
selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety Standard. Si ces normes
ne sont pas pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles.
Cet appareil doit être utilisé uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée ou mobile (É.-U. seulement) installée à demeure
si les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de renseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifiée est
fournie.
This vented gas fireplace heater is not for use with air filters. Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY
POUR UTILISATION UNIQUEMENT AVEC LES PORTES EN VERRE CERTIFIÉES AVEC
L'APPAREIL
For Use Only with Barrier (Part # 776-109/P)
Utiliser uniquement avec l’écran ( n ° 776-109/P)
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
562
562
DOOR SEAL: Please
check that the door is
properly sealed
FPI Fireplace Products International Ltd. Delta, BC, Canada
Minimum Clearances to Combustibles / Rear Vent—Clean Finish
Dégagements minimaux par rapport aux matériaux combustibles
Serial No./ No de série
920-418a
Electrical supply/Alimentation électrique 115VAC, 1.5A, 60Hz. CATEGORY/CATÉGORIE 1
NOT FOR USE WITH SOLID FUELS /
NE PAS UTILISER AVEC UN COMBUSTIBLE SOLIDE
Made in Canada/ Fabriqué au Canada
Duplicate S/N
(
See Instruction Manual for detailed instructions)
APPAREIL
FONCTIONNANT AU GAZ PROPANE
Modèle
-LP1
G600C
PROPANE GAS: Model G600C-LP1
NATURAL GAS: Model G600C-NG1
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Minimum input
Maximum input
Altitude
Pression d'alimentation minimale
Pression manifold - haute
Pression manifold - basse
Taille de l'orifice
D bit calorifique minimal
é
D bit calorifique maximal
é
Altitude
5.0" WC/C.E. (1.25 kPa)
3.8" WC/C.E. (0.94 kPa)
1.1" WC/C.E. (0.27 kPa)
#44 DMS
11,500 Btu/h
3.37 kWh
21,000 Btu/h
6.15 kWh
0-4500 ft/pi
(0-1372 m)
Part #: 920-418a
Colour: Everything black on grey except what is highlighted is printed red.
Size: File@100% 9.117’’W x 6.045’’H
Aug 27/21: Created Draft
Dec. 22/21: Updated DMS #
*
Printer
:Start serial sequence @ 000001
Pression d'alimentation minimale
Pression manifold - haute
Pression manifold - basse
Taille de l'orifice
D bit calorifique minimal
é
D bit calorifique maximal
é
Altitude
11" WC/C.E. (2.74 kPa)
10.5"
WC/C.E. ( 2.61 kPa)
2.9"
WC/C.E. (0.72 kPa)
#55 DMS
11,000 Btu/h
3.22 kWh
20,500 B tu/h 6.01 kWh
0-4500 ft/pi
(0-1372 m)
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Minimum input
Maximum input
Altitude
E
B
A
C
D
F
C #: 4001172
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE
.
Listed/Nom:
Vented Gas Fireplace Heater / Foyer au Gaz à Évacuation
Certified to/Certifi pour:
é
ANSI Z21.88:19 • CSA 2.33:19
CSA 2.17-2017
Refer to Intertek's Directory of Building Products for detailed information.
Pour plus de détails , se reporter au Répertoire des produits de construction de Intertek.
APPAREIL
FONCTIONNANT AU GAZ NATUREL
Modèle G600C-NG1
CSA P.4.1 Fireplace Efficiency (FE) /Efficacité énergétique des foyers (EEF) CSA P.4.1
Natural Gas / Gaz naturel: 64.79%
Propane Gas / Gaz propane: 66.76%
0" Clearance to combustibles from
Top, sides, and bottom of unit
0.5” Clearance to combustibles from
rear of unit
Mantel Clearances from
Fireplace Opening /
(A) 12” (305 mm) at max. depth
Side Wall Clearance from Fireplace
Opening /
B) Min 6” (152 mm)
Ceiling from Top of Fireplace
Opening:
C) Min. 44.25” (1124 mm)
Mantel Depth:
D) Max. 12” (305 mm)
Alcove Clearances:
E) Min. Width 84” (2134 mm)
F) Max. Depth 36” (914 mm)
Minimum Vent Clearances:
Horizontal Top 2” (51 mm)
Horizontal Side 1-1/2” (38 mm)
Horizontal Bottom 1-1/2” (38 mm)
Vertical Vent 1-1/2” (38 mm)
Part No. 946-556 HeatWave Kit may be used. La trousse HeatWave (pièce no. 946-556) peut être utilisée.
C
CANADIAN ENERGY
PERFORMANCE
VERIFIED
RENDEMENT
ÉNERGÉTIQUE
VÉRIFIÉ
EP5011169
Copy of Safety Decal
Decal Location
DO NOT REMOVE DECAL FROM UNIT.
Remove bottom cover—decal will
be on the floor of the unit