10 | Gi29 Direct Vent Gas Insert
owner's information
Important Message
SAVE THESE INSTRUCTIONS
The Gi29LE gas insert must be installed in
accordance with the instructions in this manual; read
them carefully before installing the unit. Consult
the authority having jurisdiction to determine the
need for permits prior to starting the installation.
It is the responsibility of the installer to ensure
this fireplace is installed in compliance with the
manufacturer’s instructions and all applicable codes.
Before You Start
We are required by the Canadian Safety Standards
and ANSI Standards to make you aware of the
following.
CLOTHING OR OTHER FLAMMABLE
MATERIAL SHOULD NOT BE PLACED
ON OR NEAR THE APPLIANCE.
CHILDREN AND ADULTS SHOULD BE
ALERTED TO THE HAZARDS OF HIGH
SURFACE TEMPERATURES, ESPE
-
CIALLY THE FIREPLACE GLASS, AND
SHOULD STAY AWAY TO AVOID BURNS
OR CLOTHING IGNITION.
INSTALLATION AND REPAIR SHOULD
BE DONE BY AN AUTHORIZED SERVICE
PERSON. THE APPLIANCE SHOULD
BE INSPECTED BEFORE USE AND AT
LEAST ANNUALLY BY A PROFESSIONAL
SERVICE PERSON. MORE FREQUENT
CLEANING MAY BE REQUIRED DUE
TO LINT FROM CARPETING, BEDDING
MATERIAL, ETC. IT IS IMPERATIVE
THAT CONTROL COMPARTMENTS,
BURNERS, AND CIRCULATING AIR
PASSAGEWAYS OF THE APPLIANCE
ARE KEPT CLEAN.
DUE TO HIGH TEMPERATURES, THE
APPLIANCE SHOULD BE LOCATED
OUT OF TRAFFIC AND AWAY FROM
FURNITURE AND DRAPERIES.
WARNING: FAILURE TO INSTALL THIS
APPLIANCE CORRECTLY WILL VOID
YOUR WARRANTY AND MAY CAUSE
A SERIOUS HOUSE FIRE.
A BARRIER DESIGNED TO REDUCE
THE RISK OF BURNS FROM THE HOT
VIEWING GLASS IS PROVIDED WITH
THIS APPLIANCE AND SHALL BE
INSTALLED FOR THE PROTECTION
OF CHILDREN AND OTHER AT-RISK
INDIVIDUALS
IF THE BARRIER BECOMES DAMAGED,
IT MUST BE REPLACED WITH THE
MANUFACTURER’S BARRIER FOR
THIS APPLIANCE.
ANY SAFETY SCREEN, GUARD, OR
BARRIER REMOVED FOR SERVICING
AN APPLIANCE MUST BE REPLACED
PRIOR TO OPERATING THE
APPLIANCE.
For Your Safety
This appliance requires air for proper combustion.
Always provide adequate combustion and ventilation
air. Follow instructions and information in CAN/CGA
B149 (in Canada) or the National Fuel Gas Code
ANSI Z223.1 (in the USA), regarding requirements
for combustion and ventilation air.
Specifications
At pressures over 1/2 psig, the pipe to the unit
must be disconnected.
Gas Max. Input Capacity:
Natural Gas 31,5
00 Btu/h (0-2000 ft../0-610 m)
30,500 Btu/h
(2,000-4,000 ft./610-1,370 m)
Propane 31,5
00 Btu/h
Min. Input
Natural Gas 17,000 Btu/h (0-2,000 ft../0-610 m)
16,500 Btu/h
(2,000-4,000 ft./610-1,370 m)
Propane 17,0
00 Btu/h
Fuels:
Approved for use with natural gas and
propane. Approved as is for use at 0' to 4,500'
(0-1,370 m).
Electrical:
120 V A.C. system.
Circulation Fan:
Variable speed, 140 CFM.
Log Set:
Ceramic fibre, 10 per set
Glass Crystals
: 2-1/2 pounds of crushed glass
Vent System:
3" (76 mm) co-linear aluminum flex
(intake & exhaust). The unit’s thermal efficiency
rating is determined under continuous operating
conditions, independent of any installed system.