Gi29 Direct Vent Gas Insert | 63
maintenance
Disconnect
5. Disconnect the green, orange, and yellow cables from the valve
Do not use the ground lug
on top of the valve
5.
Disconnect the green, orange and yellow cables from the valve.
Pilot Wires
Motor Wire
6. Slide out IFC tray and disconnect the pilot wires and motor wire
Disconnect gas flex line
Remove pilot wires
from grommet
7. Disconnect the incoming gas flex line from the ball valve. Slide the pilot wires through the grommet to remove.
6. Slide out IFC tray and disconnect the pilot wires and motor wire.
7. Disconnect the incoming gas flex line from the ball valve. Slide the pilot
wires through the grommet to remove.
9. Remove the 2 screws from each side of the valve and disconnect pilot
gas line to remove valve.
8. Remove the remaining 12 screws and lift the valve tray out.
8. Remove the remaining 12 screws and lift the valve tray out
10. Reverse steps 9-1 to replace with new gas valve assembly.
9. Remove the 2 screws from each side of the valve and disconnect pilot gas line to remove valve.
NO
TE
Wires must be secured by gray clips
when reinstalling.