Gi29 Direct Vent Gas Insert | 15
owner's information
Proflame II Remote Control Operating Instructions
Figure 2: Transmitter LCD Display
OPERATING PROCEDURE
Pairing the remote control to IFC (if required)
Power the IFC. Locate the black reset button on the lower left hand side
of the appliance. See this manual for location/instructions. The IFC will
"beep" three (3) times to indicate that it is ready to synchronize with a
Transmitter. Install the 3 AAA type batteries in the Transmitter battery bay,
located on the base of the Transmitter. (fig. 3) With the batteries already
installed in the Transmitter, push the On button. The IFC will "beep" four
times to indicate the Transmitter's command is accepted and sets to the
particular code of that Transmitter. The system is now initialized.
Figure 3: Battery Compartment
WARNING: THE TRANSMITTER AND IFC ARE RADIO
FREQUENCY DEVICES.
The Proflame 2 Transmitter provides for controlling the following hearth
appliance functions:
1. Main Burner On/Off
2. Main Burner flame modulation (6 levels)
3. Choice of standing or intermittent pilot (CPI/IPI)
4. Thermostat and Smart thermostat functions
5. Accent light modulation (6 levels)
6. Split flow valve**
7. Comfort Fan speed modulation (6 levels)
** This feature is not available on this model.
IMPORTANT:
The Proflame Transmitter 2 is an integrated part of the
Proflame 2 System, which consists of these elements:
• Proflame 2 Transmitter, to be used in conjunction with:
• Integrated Fireplaces Control (Proflame 2 IFC)
The Proflame Transmitter uses a streamline design with a simple button
layout and informative LCD display (Fig. 1). A Mode Key is provided to
index between the features and a Thermostat Key is used to turn on/
off or index through Thermostat functions (Fig. 1 & 2). Additionally, a
Key Lock feature is provided (Fig. 22).
TECHNICAL DATA
REMOTE CONTROL
Supply Voltage
4.5V (three 1.5V AAA batteries)
Ambient temperature
ratings
0 - 50
o
C (32 - 122
o
F)
Radio Frequency
315 MHZ
ATTENTION!
- Turn “OFF” the main gas supply of the appliance during installation or
maintenance of the IFC.
- Turn “OFF” main gas supply to the appliance prior to removing or
reinserting the batteries.
- In case of remote control malfunction, turn off the IFC device using
the "ON/OFF" main switch.
- For installation / maintenance, switch off the IFC device removing main
power supply plug.
Figure 1: Proflame Transmitter
Summary of Contents for Gi29LE
Page 72: ...72 Gi29 Direct Vent Gas Insert warranty ...
Page 73: ...Gi29 Direct Vent Gas Insert 73 notes ...
Page 74: ...74 Gi29 Direct Vent Gas Insert notes ...
Page 75: ......