20 | Gi29 Direct Vent Gas Insert
installation
Diagram 1
Minimum Clearances to Combustibles
Clearance
Dimension
Measured From:
A: Sidewall
8" / 203 mm
***From inside edge of faceplate / doors
B: Ceiling
60" / 1524 mm
From base of unit
D: Min. Hearth Depth
12" / 305 mm
Not required if unit raised 3" (76 mm) off the
floor.
E: Min. Hearth Width
36"/ 914 mm
Not required if unit raised 3" (76 mm) off the
floor.
K: Min. Alcove Width
54" / 1372 mm
L: Max. Alcove Depth
36" / 914 mm
From the front of the unit.
M: Mantel Deflector
2-1/2"/ 89 mm*
A
B
E
K
D
L
J***
NO
TES
•
A 36” (914 mm) wide x 12” (305 mm) deep, non-combustible hearth
is required in front of the appliance unless the unit is raised 3” (76 mm) off the floor.
•
*An optional 2-1/2" (64 mm) mantel deflector reduces the mantel height to 13" (330 mm) from
the top of the unit @ 1" (25 mm) depth.
•
(J): ***Measured from the inside edge of the faceplate/doors - reference only: 27-1/4'' (692 mm)
The clearances listed below are minimum distances unless otherwise stated.
A major cause of fires is failure to maintain required clearances (airspace) to combustible materials. It is of the greatest importance that this decorative gas
appliance is installed only in accordance with these instructions.
Summary of Contents for Gi29LE