56
|
Regency Excalibur
®
P90EX Direct Vent Gas Stove
maintenance
To Remove the Valve Only
1.
Remove pilot nut with 11mm (7/16”) wrench
(Diagram 1). Then remove burner supply tube
from 90 degree brass fitting on valve with 15mm
(5/8”) wrench (Diagram 2). Once the supply
tube has been removed from the 90 degree
brass fitting remove the 90 degree brass fitting
from the valve with a 17 mm (11/16”) wrench
(Diagram 3). Lastly remove supply tube from
valve with 22 mm (7/8”) wrench (Diagram
4).
Note orientation of 90 Degree Brass
fitting.
2.
Remove two (2) Phillips head screws on each
side of the bracket, then remove valve from
mounting bracket.
Diagram 1
Diagram 2
Diagram 3
Diagram 4
Diagram 5
3.
Reverse the steps to reinstall new valve.