34
|
Regency Excalibur
®
P90EX Direct Vent Gas Stove
installation
Horizontal Venting with Two (2) 90
o
Elbows
Horizontal Venting with Three (3) 90
o
Elbows
One 90
o
elbow = Two 45
o
elbows.
Option V
H + H1
With these options, maxi
-
mum total pipe length is 30
feet with minimum of 6 feet
total vertical and maximum
8 feet total horizontal.
Please note minimum
1 foot between 90
o
elbows is required.
A)
6" Min. 2' Max.
B)
1' Min. 3' Max.
C)
2' Min. 4' Max.
D)
3' Min. 5' Max.
E)
4' Min. 6' Max.
F)
5' Min. 7' Max.
G)
6' Min.
8' Max.
Must Use: 5" x 8" Simpson Direct Vent Piping with FPI Increaser
Starter Collar (Part #946-605)
Must Use: 5" x 8" Simpson Direct Vent Piping with FPI
Increaser Starter Collar (Part #946-605)
One 90
o
elbow = Two 45
o
elbows.
Option V
H
V + V1 H + H1
W i t h t h e s e
options, max.
total pipe length
is 30 feet with
min. of 12 feet
total vertical and
max. 9 feet total
horizontal.
Please note
min. 1 foot
between 90
o
e l b o w s i s
required.
A)
6" Min. 1' Max. 1'6" Min. 2' Max.
B)
1' Min. 2' Max. 3' Min.
3' Max.
C)
2' Min. 2' Max. 5' Min.
4' Max.
D)
3' Min. 2' Max. 7' Min.
5' Max.
E)
4' Min. 3 Max. 9' Min.
6' Max.
F)
5' Min. 4' Max. 10' Min. 7' Max.
G)
6' Min. 5' Max. 11' Min. 8' Max.
H)
7' Min. 6' Max. 12' Min. 9' Max.
Summary of Contents for Excalibur P90EX
Page 63: ...Regency Excalibur P90EX Direct Vent Gas Stove 63 notes ...
Page 68: ...68 Regency Excalibur P90EX Direct Vent Gas Stove warranty ...
Page 69: ...Regency Excalibur P90EX Direct Vent Gas Stove 69 notes ...
Page 70: ...70 Regency Excalibur P90EX Direct Vent Gas Stove notes ...
Page 71: ...Regency Excalibur P90EX Direct Vent Gas Stove 71 ...