38
|
Regency Excalibur
®
P90EX Direct Vent Gas Stove
installation
Termination Cap
Chapeau
d’évacuation
Vinyl Siding
Standoff
(optional)
Wall Thimble
2 pieces
(10" Outer
Diameter)
2 x 4 or 2 x 6
2 x 4 or 2 x 6
6-7/8" dia
air intake
Conduit
d’admission d’air
de 6-7/8 po
de dia.
4" dia. flue pipe
with spring spacer
Conduit
po de dia.
de 4
avec espaceur à ressort
Screws
(3 per connection)
Screws
Vis
4 par branchement
(
)
(4 per connection)
vnt-hor.eps
vnt-horf.eps
french
Bague murale
2 morceaux
(dimension
extérieure
de 10 po)
Vis
3 par branchement
(
)
4.
Separate the 2 halves of the wall thimble and
securely fasten the one with the tabs to the
outside wall making sure that the tabs are on
top and bottom. Fasten the other thimble half
to the inside wall. The thimble halves slip inside
each other and can be adjusted for 2 x 4 or 2
x 6 walls.
The liners must slip over the
collars a minimum of 1-3/8".
5.
Slip the assembled liner and termination
assembly through the thimble making sure the
termination cap faces up (there are markings
on the cap that show which way is up). This
will position the termination cap with proper
down slope for draining water. Fasten the cap
to the outer wall with the 4 supplied screws.
6.
Pull the centre 4"(100mm) liner and outer
6-7/8"(175mm) liner out enough to slip over the
flue collars of the fireplace. (You may wish to
cut the liner shorter to make it more workable.)
Do not bend liner more than 90
o
.
7.
Apply Mill Pac over the fireplace inner collar
and slip the 4"(100mm) liner down over it and
attach with 3 supplied screws.
8.
Do the same with the 6-7/8"(175mm) liner.
9.
Apply a bead of silicone between the thimble
and termination and around the outer edge of
the terminal at the wall in order to keep the
water out.
IMPORTANT:
Do not locate termination
hood where excessive snow or ice
buildup may occur. Be sure to check
vent termination area after snow falls,
and clear to prevent accidental blockage
of venting system. When using snow
blowers, make sure snow is not directed
towards vent termination area.
Note: To make
the installation
more aesthetically
p l e a s i n g , w e
recommend framing
out a square to mount
the terminal to.
Outside
Wall
Mur extérieur
Furring
Strips
Fourrures en bois
Furstrp.eps
see also c34020a.eps
furstrpf.eps
french
Offset Chart
Installation
Procedures for FPI Direct Vent
System (Flex)
1.
Locate the unit in the framing, rough in the
gas (preferably on the right side of the unit)
and the electrical (Junction block is on the left
side) on the left. Locate the centerline of the
termination and mark wall accordingly. Cut a
10"(254mm) hole in the wall (inside dimension).
Note: A 1-1/2"(38mm) clearance around
the liner must be maintained except
that only a 1" (25mm) clearance
is needed at the termination
end. We recommend framing
a 10"(254mm) x 10"(254mm)
(inside dimensions) hole to give
structural rigidity for mounting
the termination.
Note: If installing termination on a
siding covered wall, furring strips
must be used
to ensure that the
termination is not recessed into
the siding.
2.
Level the fireplace and fasten it to the framing
using nails or screws through the nailing strips.
3.
Assemble the vent assembly by applying
Mill-Pac to the 4"(100mm) inner collar of the
termination and slipping the 4"(100mm) liner
over it at least 1-3/8" (35mm). Fasten with
the 3 screws (drilling pilot holes will make this
easier). Apply Mill-Pac to the 6-7/8"(175mm)
flex pipe and slip it over the 6-7/8" outer collar
of the vent terminal at least 1-3/8"(35mm) and
fasten with the 3 screws.
NOTE:Horizontal sections must be
supported at intervals not
exceeding 3 feet (0.9 meter).
(Flame picture and performance
will be affected by sags in the
liner).
the vertical height must be increased. A poor
draft, or down drafting can result from high wind
conditions near big trees or adjoining roof lines,
in these cases, increasing the vent height may
solve the problem.
7.
Ensure vent is vertical and secure the base of
the flashing to the roof with roofing rails, slide
storm collar over the pipe section and seal with
a mastic.
8.
Install the vertical termination cap by twist-
locking it.
Note: Any closets or storage spaces,
which the vent passes through
must be enclosed.
Summary of Contents for Excalibur P90EX
Page 63: ...Regency Excalibur P90EX Direct Vent Gas Stove 63 notes ...
Page 68: ...68 Regency Excalibur P90EX Direct Vent Gas Stove warranty ...
Page 69: ...Regency Excalibur P90EX Direct Vent Gas Stove 69 notes ...
Page 70: ...70 Regency Excalibur P90EX Direct Vent Gas Stove notes ...
Page 71: ...Regency Excalibur P90EX Direct Vent Gas Stove 71 ...