Regency Excalibur
®
P90EX Direct Vent Gas Stove
installation
Rigid Pipe Adaptor
Pipe Length
Vertical
Terminal
Storm Collar
Flashing
943 or 943S
Ceiling Firestop
Pipe
Length
Adj.Pipe Length
90 Elbow
o
Horizontal
Termination
Cap
Wall Thimble
Vinyl Siding
Standoff (Optional)
Rigid Pipe Venting Systems
The minimum components required for a basic horizontal termination are:
1 Horizontal Termination Cap
1 90
o
Elbow
1 Rigid Pipe Adaptor
1 Wall Thimble
1 Length of pipe to suit wall thickness
(see chart)
1 4" x 6-5/8" to 5" x 8" increaser for 5" x 8" venting
Wall thickness is measured from the back standoffs to the inside mounting surface
of termination cap. For siding other than vinyl furring strips may be used, instead
of the vinyl siding standoff, to create a level surface to mount the vent terminal.
The Terminal must not be recessed into siding. Measure the wall thickness including
furring strips.
If a Vinyl Siding Standoff is required (it must be used with vinyl siding), measure
to outside surface of wall without siding and add 2 inches.
Horizontal and Vertical
Terminations for 4" x 6-5/8" Venting
Flat Wall Installation
Wall Thickness
(inches)
Vent Length Required
(inches)
4" - 5-1/2"
6"
7" - 8-1/2"
9"
10" - 1-1/2"
12"
9" - 14-1/2"
11" - 14-5/8" Adj. Pipe
15" - 23-1/2"
17" - 24" Adj.
Corner Installation
Wall Thickness
(inches)
Vent Length Required
(inches)
3-1/4" - 6-3/4"
11" - 14-5/8" Adj. Pipe
7-3/4" - 16-1/4"
17" - 24" Adj. Pipe
7-1/4" - 8-3/4"
6" + 12"
9" + 9"
4-1/4" - 5-3/4"
6" + 9"
When using Rigid Vent other than
Simpson Dura-Vent, 3 screws must be
used to secure rigid pipe to adaptor.
The FPI AstroCap
TM
and FPI Riser Vent terminal are certified for installations using FPI venting systems as well as Simpson Dura-Vent
®
Direct Vent, Ameri
-
can Metal Products Ameri Vent Direct Vent, Olympia Ventis DV, Security Secure Vent
®
, Selkirk Direct-Temp. AstroCap
TM
is a proprietary trademark of FPI
Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.
This product has been evaluated by Intertek
for using a Rigid Pipe Adaptor in conjunction
with Duravent Direct-Vent, Olympia Ventis DV,
Selkirk Direct-Temp, Ameri Vent Direct venting
and Security Secure Vent systems. Use of these
systems with the Rigid Pipe adaptor is deemed
acceptable and does not affect the Intertek
WHI listing of components.
WARNING:
Do not combine venting components from
different venting systems.
However use of the the AstroCap
TM
and FPI
Riser is acceptable with all systems.
Alternate
Horizontal
Termination
Caps
Summary of Contents for Excalibur P90EX
Page 63: ...Regency Excalibur P90EX Direct Vent Gas Stove 63 notes ...
Page 68: ...68 Regency Excalibur P90EX Direct Vent Gas Stove warranty ...
Page 69: ...Regency Excalibur P90EX Direct Vent Gas Stove 69 notes ...
Page 70: ...70 Regency Excalibur P90EX Direct Vent Gas Stove notes ...
Page 71: ...Regency Excalibur P90EX Direct Vent Gas Stove 71 ...