16.
Install the burner. Set the burner aera
-
tion to 5/16'' (8 mm) for LP. See aeration
adjustment details in the manual.
17.
Open the gas line. Check for gas leaks with
a proper soapy solution or leak detector.
18.
Attach the label "This unit has been
converted to LPG" near or on top of the
serial # decal.
19.
Replace yellow "NG" label with red "LPG"
label.
20.
Reinstall logs, media, door and access
panel. Turn ON the electrical supply.
21.
Turn ON using the remote control (the
remote control is still with the control
module).
22.
Check pilot flames. Correct flame pattern
has 2 strong blue flames. Refer to
"Maintenance Instructions" section of the
manual for correct flame patterns.
23.
Check operation of flame control.
24.
Air shutter should be set to a minimum of
5/16" (8 mm) open.