3. Repeat the previous step (2) with front cables.
4. Slide the front weight channel back into position and reattach the
screw at the bottom.
Extension tool
Note: Shown with front of fireplace removed to show workings of pulleys
and cables.
Annual Maintenance
Completely clean out entire unit annually
Inspect bricks
Replace any damaged parts.
Check door latch assembly. If unable to obtain a tight seal or sloppy replace door catch
Inspect condition of door frame gasket Replace if frayed or in poor condition
Check glass for cracks Replace if required
Inspect and clean chimney Annual professional chimney cleaning recommended
NOTE: Chimney Cleaning
We highly recommend that the chimney cleaning be done by a professional as they will have the necessary tools such as a proper sized
brush and special vacuum cleaner designed to deal with fine particles. This appliance does have an internal damper inside of the 8" flue.
Be careful not to damage this when cleaning the chimney. The damper will be located inside of the 8 inch flue approximately 3 feet up from inside of the
fireplace ceiling.