Rain Cap
�
-
- - - - 1 O'
- - - -
----11-i
WARNING: DO NOT
PACK REQUIRED AIR
SPACES WITH INSULATION
OR OTHER MATERIALS
2" clearance min.
Roof Top Radiation Shield
Note:
Openings
must be framed to
adequately support
any chimney supports
and roof assemblies
WARNING: -----+---====:1i1
MAJOR RISK
OF FIRE, LOOSE
FILL INSULATION
MUST NOT GO
ABOVE THE
RADIATION SHIELD
AND MUST NEVER
COME IN CONTACT
WITH THE CHIMNEY
The chimney
must be enclosed
when it passes through
living spaces: 2" clearance
min. with the chimney
Refer to
"Canada Only"
section if installed in
Canada
t
2' min.
Figure 13 General Chimney Installation
CANADA ONLY:
Flashing
with a
Storm Collar
•
3' min.
A flexible radiation shield tube (RM-12RRSF) must be installed around the
chimney when it is enclosed. This includes an outside chase. In the fireplace
enclosure the flexible radiation shield tube is not required.
The radiation shield (RM-12RRS2) must be used with its ring at the first ceiling
above the fireplace. All subsequent floors require a radiation shield without the
ring installed.
Once a radiation shield is installed to pass through a floor, install a length of
chimney and then insert a flexible radiation shield tube over it. The ends of the
flexible radiation shield tube are not the same size. The smaller end goes
towards the floor while the larger end goes towards the ceiling. Make sure to
insert the flexible radiation shield tube in the appropriate orientation around
z
0
z
1-1
23
General Chimney Installation
Note: Nailing strips differ than shown in diagram
Anchor plate
NOTE: It is recommended to enclose chimney with
proper clearances with blown-in insulation.
Chimney installation
CF780 Wood Fireplace
|
19