18
|
Bellavista® B36XTCE-11 Gas Fireplace
installation
Caution Requirements
The top, back and sides of the fireplace are defined by
standoffs. The metal ends of the standoff may
NOT
be
recessed into combustible construction.
WARNING
Fire hazard is an extreme risk
if these clearances (air space) to combustible materials are not
adhered to. It is of greatest importance that this fireplace and vent
system be installed only in accordance with these instructions.
CLEARANCES
The clearances listed below are minimum distances unless otherwise stated.
A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance
that this fireplace and vent system be installed only in accordance with these instructions.
B36XTCE Clearance Requirements
Minimum Vent Clearances
to Combustibles
Clearance:
Dimension
Measured From:
A: Mantel Height (min.)
21-1/4" (540mm)
Top of Fireplace Opening
B: Sidewall
12" (305mm) one side
only
Side of Fireplace Opening
C: Ceiling
39" (991mm)
Top of Fireplace Opening
D: Mantel Depth (max.)
12" (305mm)
29-1/4 " (743mm) from
Top of Fireplace Opening
E: Alcove Width
84" (2134mm)
Wall to Wall (Minimum)
F: Alcove Depth
36" (914mm)
Front to Back Wall (Maximum)
Notes:
0"
No Hearth Required
Horizontal Top
2" (51mm)
Horizontal Side
1-1/2 " (38mm)
Horizontal Bottom
1-1/2" (38mm)
Vertical Vent
1-1/2" (38mm)
Alcove
E
F
C
D
A
E
F
C
Close to Ceiling
F
E