20
|
Bellavista® B36XTCE-11 Gas Fireplace
installation
MANTEL LEG CLEARANCES
NON- COMBUSTIBLE REQUIREMENTS:
See framing dimensions on next page.
NOTE
: The 9-1/4" x 40-5/8" non combustible material supplied with this unit can be replaced if trying to achieve a clean finish. A large piece of non
combustible material (ie. 4' x 8' x 1/2") can be used to eliminate taped seams on or near unit.
*Optional : Steel stud may be placed below the original steel stud on edge only when appliance is in place for ease of securing non-combustible
material.
6.5"
3.5”
Mantel leg
Mantel leg
Allowable mantel leg
projection.
3"
1-1/2"
TopView
12"
Side opening
of fireplace
32-7/8"
835mm
2
5
-5
/8
"
[6
5
1
m
m
]
NO FACING OR
FINISHING MATERIAL
IN THIS AREA
No Combustible
Materials in this Area
4
7
-3
/8
"
[1
2
0
3
m
m
]
40-5/8"
[1032mm]
4-1/8"
[105mm]
8-3/8"
[213mm]
3-7/8"
[98mm]
9-1/4"
[235mm]
Non combustible - supplied w/unit
*