Bellavista® B36XTCE-11 Gas Fireplace
|
41
installation
16
16
22
22
00
0 0
12
12
12
12
66
66
18
18
44
49"
(1245mm)
Minimum
Height
Requirement
44
14
14
88
88
10
10
10
10
14
14
16
16
18
18
20
20
V
ertical Height (Feet)
Horizontal (Feet)
Restrictor 2-1/4” Open
Set 1
No Vent Restrictor
VENTING ARRANGEMENTS FOR HORIZONTAL TERMINATIONS
RIGID PIPE 4" X 6-5/8"
(MUST USE REDUCER & RIGID PIPE ADAPTOR (PARTS # 946-606 & 770-994)
The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90
o
(two 45
o
elbows equal one 90
o
elbow).
• Maintain clearances to combustibles as listed in "Clearances" section
• Horizontal vent must be supported every 3 feet.
• Firestops are required at each floor level and whenever passing through a wall.
• A wall thimble is mandatory for all horizontal terminations due to high temperatures.
ALL RIGID PIPE SYSTEMS
4" INNER DIAMETER
6-5/8" OUTER DIAMETER