22
|
Bellavista® B36XTCE-11 Gas Fireplace
installation
FRAMING & FINISHING
1. Frame in the enclosure for the unit with framing material.
Note: When constructing the framed opening, please ensure there is access to install the gas lines when the unit is installed.
2. For exterior walls, insulate the enclosure to the same degree as the rest of the house; apply vapour barrier and drywall, as per local installation codes.
(Do not insulate the fireplace itself.)
WARNING: Failure to insulate and add vapor barriers to the inside of the exterior wall will result in operational and performance problems including, but
not limited to: excessive condensation on glass doors, poor flame package, carbon, blue flames etc. These are not product related issues.
3. The unit does not have to be completely enclosed in a chase. You must maintain clearances from the vent to combustible materials: See "Clearances"
section. Combustible materials can be laid against the side and back standoffs and the stove base.
4. Tile Finish Option 1: Drywall may be installed only in areas as shown below to create a surface to apply finishing materials such as tile, slate, etc.
5. Tile Finish Option 2: If applying a non-combustible finishing material (tile,slate,etc) the material can be installed directly onto the metal surface (clean
front) of the unit in the area shown below.
1/2" DRYWALL
NON-COMBUSTIBLE FACING
FOR CLEAN LOOK
(ie. painted finish)
40-5/8"
[1032mm]
4
7
-3
/8
"
[1
2
0
3
m
m
]
1/2" DRYWALL
DO NOT EXTEND
DRYWALL ONTO METAL
SURFACE OF UNIT.
WOOD STUD
NON-COMBUSTIBLE BOARD - SUPPLIED WITH UNIT
DO NOT EXTEND
DRYWALL ONTO METAL
SURFACE OF UNIT
1/2’’ DRYWALL
DO NOT EXTEND
DRYWALL ONTO METAL
SURFACE OF UNIT
32-7/8"
835mm
2
5
-5
/8
"
[6
5
1
m
m
]
Combustible and Non-combustible Facing and Finishing
Materials around unit.
CLEAN FINISH
TILE FINISH
6. If applying a non-combustible facing it may be installed over the metal surface (clean front) of the unit in the area shown below.
Combustible
Material (ie: 1/2’’ Drywall)
Non-combustible
Finishing Material
Only
Non-combustible Material (9-1/4" x 40-5/8")
Finishing Material
Only
Nailing Strip -flush with unit
Combustible
Materia
l
(ie: 1/2’’ Drywall)
Non-combustible
Supplied with Unit
1-1/2
(38mm)
Ensure finished
material is
brought to lip
*NOTE:
The 9-1/4" x 40-5/8" non combustible material supplied with this unit can be replaced if trying to achieve a clean finish. A large piece of non com-
bustible material (ie. 4' x 8' x 1/2") can be used to eliminate taped seams on or near unit.
*
Summary of Contents for B36XTCE-11
Page 70: ...70 Bellavista B36XTCE 11 Gas Fireplace parts list 13 12 19 40 38 39 41 MAIN ASSEMBLY ...
Page 76: ...76 Bellavista B36XTCE 11 Gas Fireplace warranty ...
Page 77: ...Bellavista B36XTCE 11 Gas Fireplace 77 notes ...
Page 78: ...78 Bellavista B36XTCE 11 Gas Fireplace notes ...