Configuration software
SAFEGATE ACTIVATION
The actual operation and display of the curtain status is obtained via two successive commands:
¾
Disconnect
(icon
).
SAFEGATE is now operative.
¾
Monitor curtain status
(icon
).
CURTAIN CONDITION MONITORING
At this stage we have a DYNAMIC reading of the SAFEGATE operating condition.
In particular, they are highlighted:
¾
A graphic representation of the curtain, with integrated lamp (if present) with colouration in real time.
¾
A graphic representation of the colour-coded label in real time. Programming blue led and Communication
yellow led on =
Curtain is programmed and communicating.
CONFIGURATION DELETION
Using the
icon
, the operator can delete the configuration uploaded on the barrier
(level 2 password).
SETTING CURTAIN GENERAL PARAMETERS
Automatic/Manual:
This parameter allows you to communicate the desired operating mode to SAFEGATE
(refer to section "OPERATING MODES SELECTION").
Enable FBK K1/K2:
If selected, it is mandatory to read an external EDM signal (refer to section
"SELECTING MODES OF OPERATION").
FBK K1/K2 reading time:
Lets you set a delay in reading the external FBK signal.
Possible values: from 100 ms to 1300 ms (with 100 ms steps).