E) 2 EXTERNAL CROSS INTEGRATED MUTING SENSORS, FOR BI-DIRECTIONAL GATES (TX).
This mode is bidirectional and is useful for protecting gates with pallet output.
Î
Î
The crossing point of the two Muting sensors must be placed inside the hazardous area to avoid
undesirable and dangerous activations of the Muting function.
The activation of the Muting function occurs after the simultaneous interruption (within max 4 sec) of
sensors S1 and S2. As long as both sensors remain busy, the Muting function continues. When the first
of the two sensors is released, the Muting function is disabled. In this mode of operation the maximum
duration of the Muting condition (timeout) can be selected in 30 seconds or 9 hours.
Î
Î
Other timings are available with programmable programs.