SAFETY PRECAUTIONS
x
Always use extreme caution when entering or exiting the platform.
Be sure that the platform is fully lowered before exiting the
platform.
x
Always maintain three points of contact with the machine. “3 point
contact” means using two hands and one foot or two feet and one
hand at all times while entering or exiting the platform.
Electrocution Hazard
x
This machine is not insulated and
will not provide protection from
contact or proximity to electrical
current.
x
Maintain distance from electrical
lines, apparatus or any energized
(exposed or insulated) parts
according to the Minimum
Approach Distance (MAD) as
shown in Table 1-1.
x
Allow clearance for machine
movement and electrical
line swaying.
Table 1-1
Minimum Approach Distances (M.A.D.)
VOLTAGE RANGE
(PHASE TO PHASE)
MINIMUM SAFE APPROACH
DISTANCE - FEET
(METERS)
0-50KV
10 (3)
Over 50KV to 200KV
15 (5)
Over 200KV to 350KV
20 (6)
Over 350KV to 500KV
25 (8)
Over 500KV to 750KV
35 (11)
Over 750KV to 1000KV
45 (14)
NOTE:
This requirement shall apply except where employer, local or
governmental regulations are more stringent.