2) Probe Calibration
1. Fix a material of flat surface on the clamp.
2. Press the
button and go to the expert menu mode.
3. Press
button, and when
menu appears on the LCD window, then press
and hold
button for more than 3 second until it beeps (more than 3 seconds) to run the menu.
4. Select the “
2.Probe
” then press and hold
button until it beeps (more than 3 seconds) to run the menu.
5. When
appears on the LCD window, press
button to appear
on the LCD window, then press Z axis
button to lower the tool to make it
close to the materials, and release the tool by using a wrench until the tool touches the materials. Then tighten the
tool.
6. Press and hold
button until it beeps (more than 3 seconds), then the probe measures the height of the
materials and the length of the tool before the settings is saved.
7. Press and hold
button until it beeps (more than 3 seconds) to begin a test run.
At this time, the tool draws four lines on the materials. If two lines out of four lines are seen one the materials,
then it is appropriate. If three lines are seen on the materials, then press
button to raise it by 0.05mm,
and one line is seen, then press Z axis
button to lower it down by 0.05mm
※
0.05mm per line .
Summary of Contents for R&D MAGIC-70
Page 13: ...12 R Communication port Connects USB cable to the computer ...
Page 22: ...21 If the thickness of ring is not even mix different sized chuck fingers to hold it ...
Page 27: ...26 ...
Page 31: ...30 ...
Page 36: ...35 Left top Origin point Left bottom Origin point Center Origin point ...
Page 101: ...100 ...
Page 113: ...112 3 Drag the work area by the mouse and decide picture size to load the picture ...
Page 117: ...116 3 Click File Import button from the Magic Art menu to import a file ...
Page 119: ...118 ...
Page 123: ...122 ...