AN-50e
user manual
70-00033-01-03
Proprietary Redline Communications © 2005
September
2005
Page 26 of 100
longer than five seconds activates a long-reset and some parameters are changed to
the factory default settings. Refer to the following table for details.
Table 9
:
Overview - Front Panel Reset Switch
Operation
Result
Depress
switch < 5
seconds.
Statistical values are reset.
Click the System Reset button at the bottom of the
System Configuration screen to reset the system. This
may be done remotely from the Web maintenance tool.
Depress
switch > 5
seconds.
Reload the factory default configuration for the following
settings: IP Address, IP Subnet Mask, Channel, System
Name, Username, and Password.
Refer to 5.1: Factory Default Settings on page 71.
2.3
System Radio (Outdoor Unit)
2.3.1 Transceiver
The radio transceiver is housed in an aluminum alloy case. The connectors are
listed in the following sections.
Figure 6
:
Overview - Transceiver
IF Port (Radio Control)
The transceiver IF port (female F-type connector) is for communications with the
indoor terminal. This port is connected to the terminal using coaxial cable.
RF Connector
The transceiver RF port (female N-type connector) is for sending/receiving the RF
signal to/from the antenna. A short coaxial cable is provided to connect the
transceiver to the antenna.
Alignment Pin and Audible Signal
For basic alignment using the received signal, an alignment buzzer (intermittent
tone sweep generator) is available on all transceivers. A faster repetition rate of the
buzzer indicates a stronger the signal is being received from the remote end. Some
transceivers also have a voltage alignment pin. On equipped systems, you can
adjust for a voltage peak using a DC voltmeter. Use the Web interface to select
either the buzzer or voltage alignment pin.