1.5 UL
Information
- The equipment must be properly grounded according with NEC and other local
safety code requirements
- Caution for all AC and DC models: Double Pole/Neutral Fusing.
- The DC source must be fused at Time Delay 2.5A, 250V.
- The DC input wiring must be minimum 18 AWG.
- The DC input source must be SELV.
- The DC input source must comply with local electrical codes.
- To meet the over voltage safety requirements on the telecommunications
cables, a minimum 26 AWG telecommunication line cord must be used.
- "Pour être en conformance avec les exigences finies de sûreté de sur-tension sur
les câbles de télécommunications un fil de télécommunication ayant un caliber
minimum de 26 AWG doit être utilisé."
- Reminder to all the BWA system installers: Attention to Section 820-40 of the
NEC which provides guidelines for proper grounding and, in particular,
specifies that the cable ground shall be connected to the grounding system of
the building, as close to the point of cable entry as is practical.
1.6 ENTELA
The AN-50e system is ENTELA approved for health and safety.