AN-50e
user manual
70-00033-01-03
Proprietary Redline Communications © 2005
September
2005
Page 41 of 100
DFS Antenna Gain
: Enter the gain (dBm) for the system antenna.
It is important that the DFS Antenna Gain matches the actual antenna gain.
If the DFS Antenna Gain is set higher than the true antenna gain, the system is less
sensitive to detecting interference, and is not operating in compliance with the
UK/ETSI standard. If the DFS Antenna Gain is set lower than the true antenna
gain, the system is more sensitive to interference and this may result in false DFS
triggers.
Note: This hardware-enabled feature is not available on the AN-50.
Controls
Save
: Click this button to save the current parameter settings. Note that when
certain parameters are changed clicking Save initiates a system reset.
Test
: Click this button to have the system reset using the current configuration
settings. After a period of five minutes, the system resets using the previously
saved settings and current settings is lost. Click the Save button at any time to save
the current changes.
System Reset
: Click this button to boot the system. Resets all statistics and
unsaved changes to the configuration is lost.