5.4
System Error Log Messages
The following table provides a brief description of the key messages recorded in
the logs by the system.
Table 28
:
Diag. - System Log Messages
Log Message
Description
100-Parameters loaded
successfully!
All system parameters have been successfully downloaded.
101-Firmware configuration OK!
The onboard firmware configuration has been properly set
up.
102-Ethernet port configured!
The Ethernet port has been properly configured and is
operational.
103-Parameters saved
successfully!
The latest configuration parameters have been successfully
saved into the system memory.
104-Upgrade OK!
The software upgrade process completed successfully.
105-Password changed
successfully!
The system password was successfully changed.
106-Firmware programmed OK!
The firmware was successfully programmed.
107-Statistics initialized!
Reset of statistics was successful.
108-Version control loaded
successfully!
Software version control data was successfully loaded.
109-Options Key activated!
Product Options Key was accepted.
110-Options Key already used!
The Product Options Key was not accepted because it was
already used once. Contact your local Redline
representative.
111-SNMP configuration loaded
successfully!
The SNMP configuration was successfully loaded.
201-EEPROM corrupted. Def.
param. loaded!
The memory area containing the system configuration has
been corrupted. Default parameters loaded.
202-Error while saving
parameters!
The latest configuration parameters have not been
successfully saved. In this case, repeat the save
configuration process to try to resolve the problem.
203-Another upgrade in
progress!
The system is already in upgrade mode, in the event the
operator inadvertently invoked multiple simultaneous
upgrades.
204-Invalid upgrade parameters!
The parameter entered is in error. If this message appears,
check for typing errors.
205-Upgrade failed!
The software upgrade process completed unsuccessfully.
206-Password changed
unsuccessfully!
The new password entered into the system was not
successful. In this case, repeat the process.
207-Timeout on reading data
packet!
The system has timeout looking for packets from the host
computer or server. Check for obvious problems such as
disconnected or faulty cable.
209-TFTP error received!
The Trivial File Transfer Protocol (TFTP) routine used to
download the software to the terminal during the Upgrade
process failed. Likely cause is disconnected or faulty cable.
210-Error: TFTP unknown
message!
The TFTP client received an unknown message. In this
case, repeat the upgrade process.
211-Error: while writing flash!
While writing the new software into terminal flash memory
an unexpected error occurred. Try to repeat the process and
if the error persists contact your local representative.