Operation
6
BAL_S20_EN_1V0_REC_121-006454590
23/ 33
Key
Operating mode
Function
Automatic mode with total
opening width
This operating mode is the standard operating mode.
Through triggering of a e.g. Radar, the door opens. After
the pre-set door time delay, the door closes.
Continuously open and manual
mode
Door opens and stays in open position. The door can be
moved manually.
One-Way
The door opens only through a triggering of an e.g. radar
which is on the inside of the door, or through a optional key
operated contact (SSK).
Locking
The door will be locked after a completed closing. The door
can only be opened with the last pre-set opening width
through a key operated contact (SSK).
Caution:
During a
Power loss
the opening of a locked
door might be only possible with a optional battery pack or
a manual locking device!
Operating mode display
The BDE-M has only 1 LED. The LED is lightening if mains voltage or battery voltage are available.
Reset-Button
This hidden button will be actuated with a 25 mm long paper clip.
Therefore there is a little hole in the middle of the logo.
If the reset-button will be pressed for about 5 seconds, a software-reset will happen. The pre-set set-
tings remain unaffected.
Locking the control panel with the keyboard
IMPORTANT
Standard EN 16005 requires protection of the selection of the mode of ope-
ration of pedestrian automatic doors used as emergency exits so that they
may not be inadvertently locked when the building is in use.
If a "locked" mode of operation is available, the mode of operation must be protected, e.g. by an ac-
cess code or a key, so that changes can only be made by authorised personnel.
It is the responsibility of the operator of the pedestrian automatic door used as an emergency
exit to lock the control panel into automatic position when the facility is being used.
Key sequence
Display
Description
Locking the control unit
▪
Undesired manipulation of the control unit is hindered
▪
Panel is locked
▪
Locked status of the BDE-D is displayed
Unlocking the control unit
▪
Free selection of operating modes and special functions
is ensured
6.5.1
6.5.2
6.6