Operation
6
BAL_S20_EN_1V0_REC_121-006454590
19/ 33
Technical data
NOTICE
The power connection must be installed by a licensed electrician.
The power must be able to be shut off via a main switch or residual current
circuit breaker (on-site).
NOTICE
For underfloor drives, an FI should be installed by the customer.
Description
Designation
Underfloor sliding door system (complete door s.) S20 SU
Door drive (incl. drive module)
STA20 SU
STA20 SU RED
STA20 SU DUO
STA22 SU RED
STA22 SU DUO
Drive module
ATM20 SU
ATM20 SU RED
ATM20 SU DUO
ATM22 SU RED
ATM22 SU DUO
Dimensions
Opening width A
800 mm
to 3ʹ000 mm
Passage height G
max. 3ʹ000 mm
Max. Door leaf inclination
± 10°
Underfloor drive Width
≤ 330 mm
Underfloor drive Depth
≤ 180 mm
Underfloor drive Length
1ʹ800 mm to 6ʹ500 mm
Max. Door leaf weights
Typ
STA20 SU
STA20 SU DUO/RED
STA22 SU DUO/RED
D-STA
2 × 120 kg
2 × 150 kg
2 × 200 kg
E-STA
1 × 150 kg
1 × 200 kg
1 × 250 kg
Electrical connection data
Mains voltage:
100-240V AC (STA 20) / 115V AC (Series 5100)
Frequency:
50-60 Hz
Mains fuse:
Max. 16A circuit breaker with tripping characteris-
tic C or K
Power consumption:
Max.: 700 VA
Control voltage:
24V DC (safety extra-low voltage)
Protection class:
1
Degree of protection:
IP 20
Environmental conditions
Temperature range
-15°C to +50°C
Moisture range
up to 85% rel. humidity, non-condensing
Protection class drive module
IP44
5