DATA PLATE
(Affixed to the base of the unit for reference to gas pressure & consumption)
MODEL ELEMENT 1200
GAS TYPE
Natural Gas
Max – Min inlet pressure range
Natural gas 1.13kPa – 5.00kPa
3 X 2.30 mm
0.88 kPa High / 0.60 kPa Low
INJECTOR SIZE
TPP
N.G.C. (Mj/hr)
39 High/32 Low
Aeration settings DS 1800 MODEL
Media setup NAT GAS
Redgum with large ceramic coals 3.5 / 6.0 / 6.0mm RH end
Redgum with glass pebbles 1.5 / 2.5 / 2.5mm RH end
Glass pebbles only 1.5 / 2.5 / 2.5mm RH end
Ceramic pebbles only 1.5 / 3.0 / 3.0mm RH end
Ceramic pebbles with glass pebbles 1.5 / 3.0 / 3.0mm RH end
Forestwood with broken glass 2.0 / 4.0 / 4.0mm RH end
Forestwood with glass pebbles 1.5 / 2.5 / 2.5mm RH end
Driftwood with glass pebbles 1.5 / 2.5 / 2.5mm RH end
Driftwood with small ceramic coals 2.0 / 4.0 / 4.0mm RH end
LH end
RH end